Conitscting generator to main electrical supply, Before starting engine, Ikcaution – Sears 919.329150 User Manual

Page 14: Gasoline, Ikwarning, To start yoir generator

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Conitscting Generator To Main Electrical

Supply

PotentiaJ hazards exist when a electrical generator Is

connected to the main electrical supply coming Into
the house. It is at that point that the generator could
feed back into the utility company's system causing
posable electrocution of workers who are repairing

eteetrical lines. To avoid back feeding of electricity into
utility systems, a double-throw transfer switch

should be installed between the generator and utility

power. This device should be Installed by a licensed
electrician and in compliance with all local electrical
codes.

NOTE: When Installing a Double-Throw Transfer
Switch, a minimum of 10 gauge wiring must be used.

BEFORE STARTING ENGINE

ikCAUTION

I

Always check engine oil level
before every start Running

engine low of oU or out of oil could reeutt fe

serious damage to the engine.

Adding Engine Oil

Your generator has been shipped wWiout oil in the
engine. Begin by removing the OH dipetick and plug.

Start pouring the oil In slowly.

The engine will hold approximately 26 ounces of oil. To

check the oil, clean and replace the dipstidc. Do not
screw the dip stick in when checking the oR level. Next,
remove the dipstick to check the level. The oil dipstick
Is clearly marked with tines that tell you when the

engine has enough oil. Do not fill above this point.

Ч \\ GLEAN

NOTBe When adding oil to the engine orar^cease, use a
high quality detergent oil classified ‘For Service
SF,SG,SH’' rated SA£30 weight Use no special additives.
Select fee dl'ls viscosity grade according to your expected
operating temp«etures.

saeWscwHvCreii—

п

_J

т

п

' ^

— М------ * *— «-I

SiMiniioiwPBWIVM tuHOB mne»tstD wmisimroiLOH«>i«l

Gasoline

Your generator engine is 4 cycle. Use unleaded fuel
only. Never mix oil with gasdine.

• Remove gas cap.

■ Add unleaded gasoline, sicwviy, to fuel tank.

Use dean, fresh, n^lar unleaded geeoltne with a
minimum of 65 octane. Do not mix oil with gasoline.

ikCAUTION

(

Never fin fuel tank com­
pletely. Fill tank to 1/2'

below the bottom of the ffller neck to provide
space for fuel expansion. Wipe any fuel spIRage
from engkie and equipment before starting
engine.

Do not overfilt.

ikWARNING

[

Never fill ftiel tank indoors.
Never fill fuel tank when

engine ie running or hot. Do not smoke when
filling fuel tank.

To Start Yoir Generator

ikCAUTION

JNever run engine indoars or

I

In enclosed, poor ventilated

areee. Engine exhaust contains carbon monox­
ide, an odorlese and deadly gee.

IMPORTAN'R Make sure the battery is properly
serviced, fully charged, and assembled befmo starting.

• Open the fuel shut-off valve. Him counter clock­

wise until the vdve stops.

• Move the choke control located on fee engine to

•FULL CHOKE" position.

№ми Пвк.автоо

14 -

eng