beautypg.com

A check-up checklist, Before you request a service call – Carrier 58CMA User Manual

Page 7

background image

7

If you have replaced a disposable filter with a perma-
nent washable filter, it may be cleaned if it is dirty.
Wash filter in a sink, bathtub, or outside with a garden
hose. Always use cold tap water. A mild liquid deter-
gent may be used if necessary. Spray water through
filter in the opposite direction of airflow. Allow filter
to dry.

5. Re-install clean air filter.

6. Turn on electrical supply to furnace.

A CHECK-UP CHECKLIST

Your furnace represents an important investment in
your family’s comfort and your home’s value. To keep
it performing properly and as a preventative to future
problems, have a trained service specialist give your
furnace a professional check-up annually. The fol-
lowing checklist can be used as a guideline to proper
service:

• Check flue and secondary tube passage ways including
chimney —

clean if necessary.

• Change oil filter.

• Change nozzle.

• Check and adjust combustion and draft.

• Inspect all vent piping inside structure for deterioration
and vent terminations outside the structure for blockage.

• Check oil pipes leading to and inside of your furnace
for leaks.

• Inspect and clean the blower motor and wheel.

• Inspect and change or clean air filter if necessary.

• Inspect all supply- and return-air ducts for obstruc-
tions, air leaks, and insulation. Remedy any problem
when necessary.

• Inspect the return-air duct connections at the furnace to
ensure it is physically sound, sealed to the furnace
casing, and terminates outside the space containing the
furnace.

• Inspect electrical wiring, connections, and components
for loose connections.

• Examine the physical support of the furnace. Support
should be sound with no cracks, sagging, gaps, etc.
around the base.

• Check furnace for any obvious signs of deterioration.

BEFORE YOU REQUEST
A SERVICE CALL

If your furnace is not operating or not performing
properly, you may save the expense of a service call by
checking a few things yourself before calling for
service.

FOR INSUFFICIENT AIRFLOW:

• Check for dirty air filters.

• Check for blocked return-air or supply-air grilles
throughout your home. Ensure they are open and
unobstructed.

If problem still exists, call your dealer for service.

IF FURNACE FAILS TO OPERATE:

Follow this checklist step by step, advancing to the next
step only if furnace fails to start.

• Check thermostat for proper temperature. Is thermostat
set above room temperature?

• Is thermostat set on HEAT?

• Check fuses and circuit breakers. Is electrical supply
on?

• Is valve in oil supply pipe in open position?

• Is the ignition control on the burner not in lockout? The
red button on top of the control must be depressed for 3
sec in order to reset the control.

• Check for obstructions around the vent termination.

If furnace still fails to operate, call your service represen-
tative. For your convenience, record furnace product and
serial numbers on page 2. Should you ever require ser-
vice, you will have ready access to the information need-
ed by your service representative.