Introduction, Warning, Preparing for the new installation – Sears 153333531 User Manual
Page 5
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Introduction
Thank You
for purchasirrg a Sears water heater.
Properly installed and maintaiiied, it should give you years of
trouble free service. If you should decide that you want the new
water heater professionally installed by Sears contact the local
Sears Service Center or any Sears store, They will arrange for
prompt, quality installation by Sears authorized contractors.
Abbreviations Found In This Instruction Manual
A.G.A, - American Gas Association
A. N.S.I, - American National Standards Institute
N.F PA. - National Fire Protection Association
WARNING
This gas-fired water heater is design certified by the
American
Gas
Association
Laboratories
under
American
National
Standards
for
Gas
Water
Heaters,
The instaflation must conform with this manual, Local
Codes and with the latest edition of,the National Fuel
Gas Code, ANSI Z223.1.
This
publication
is
available
from
ypur
local
govern
ment
or
public
library,
gas
company,
or
by
writing
NFPA, Batterymarch Park, Quincy, MA 02269.
MODEL
NUMBER
TANK
CAPACITY
IN GALLONS
TYPE
OF
GAS
B.T.U.
RATE
RECOVERY RATE
GALS. PER HOUR
®90'F RISE
MINIMUM
VENT
PIPE
DIMENSIONS IN INCHES
DIAMETER
HEIGHT
TO
JACKET TOP
153.333000
30
NATURAL
30,000
31,0
3”
16"
56"
153.333030
30
NATURAL
30,000
31.0
3"
16"
56"
153.333031
30
NATURAL
30,000
31.0
3"
16"
56"
153.333100
40
NATURAL
32,000
33.0
3"
18"
56’A"
153.333130
40
NATURAL
32,000
33.0
3"
18"
56*//'
153.333131
40
NATURAL
32,000
33.0
3"
18"
56'//'
153.333530
SO
NATURAL
32,000
33.0
3”
20"
56V/
153.333531
50
NATURAL
32,000
33.0
3«
20"
56'//'
Preparing for the New Installation
1. Read the "General Safety" section, pages 2 and 3 of
this manual first and then the entire manual carefully. If
you don't follow the safety rules, the water heater will
not operate properly, it could cause DEATH, SERIOUS
BODILY INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation,
operation, and maintenance of the gas-fired water
heater. It also contains warnings through out the manu
al that you must read and be aware of. AM warnings
and ail instructions are essential to the proper opera
tion of the water heater and your safety. Since we can
not put everything on the first few pages,
READ THE
ENTIRE
MANUAL
BEFORE
ATTEMPTING
TO
INSTALL
OR OPERATE THE WATER HEATER.
2. The installation must conform with the instructions in
this manual; gas company rules; and Local Codes, or
in the absence of Local Codes, with the latest edition
of the National Fuel Gas code, ANSI Z223 1, also
referred to as NFPA 54. This publication is available
from your local government or public library or gas
company or by writing NFPA, Batterymarch Park,
Quincy, MA 02269,
If after reading this manual you have any questions or
do not understand any portion of the instructions, cal!
the Sears Service Center
Carefully plan the place where you are going to put the
water heater. Correct combustion, vent action, and vent
pipe installation are very important in preventing death
from possible carbon monoxide poisoning and fires
Examine the location to ensure the water heater com
plies with the "Locating the New Water Heater" sec
tion in this manual.
For California installation this water heater must be
braced, anchored, or strapped to avoid falling or mov
ing during an earthquake. See instructions for correct
installation procedures. Instructions may be obtained
from your local dealer, wholesaler, public utilities or
California Office of the State Architect, 400 P Street,
Sacramento, CA 95814..