For your ìnfortnation (cont'd), Air" m hot water faucets, High temperature shut off system – Sears 153333531 User Manual
Page 19: Warning, Not enough or no hot water, Water is too hot, Air" in hot water faucets, High temperature shut off system 19
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

For Your ìnfortnation (cont'd)
If the 'smelly water persists after the anode replacement
and chlorination treatment, we can only suggest that con
tinuous chlorination and filtering conditioning equipment
be considered to eliminate the water problem
Do not remove the anode leaving the tank unprotected.
By doing so, alt warranty on the water heater tank is
voided.
"AIR" m HOT WATER FAUCETS
HYDROGEN GAS: Hydrogen gas can be produced in a
hot water system that has not Been used for a long peri
od of time (generally two weeks or more). Hydrogen gas
is extremely flammable and explosive. To prevent the
possibility of injury under these conditions, we recom
mend the hot water faucet be opened for several min
utes at the kitchen sink before any electrical appliances
which are connected to the hot water system are used
(such as a dishwasher or washing machine). If hydrogen
gas is present, there will probably be an unusual sound
similar to air escaping through the pipe as the hot water
faucet is opened. There must be no smoking or open
flame near the faucet at the lime it is open.
HIGH TEMPERATURE SHUT OFF SYSTEM
This water heater is equipped with an automatic gas shut
off system. The high temperature shut off is built into the
gas control valve. This system shuts off the gas supply to
the water heater burners when high water temperatures
are present. It is non-resettable. If the high temperature
shut off activates, the gas control valve must be replaced,
if this were to occur, turn "OFF" the entire gas supply to
the water heater Contact the Sears Service Center,
-WARNING-
NOT ENOUGH OR NO HOT WATER
1 Check the manual gas shut off valve to be sure it is
open.
2. Check the pilot flame. It may have gone out. All mod
els have an opening behind the outer door for viewing
the pilot
3. If the pilot is not lit, follow the "lighting" instructions
in this manual or located above the gas control valve
on the water heater to relight the pilot. If the water
was extremely hot and is now cold, the high limit safe
ty temperature shut off may have put out the burner
and pilot If the high temperature shut off activates, the
gas control valve must be replaced. Contact the Sears
Service Center
4. The gas control knob must be turned to the "ON"
position.
5. The temperature adjustment dial may be set too low
See the "Temperature Regulation" section.
6
. The gas company can check the gas input to see if it is
correct An underfired water heater will not heat water
as quickly
7 Look for leaking or open hot water faucets. Make sure
all are closed.
8
The cold water inlet temperature may be colder during
the winter months. It will take longer to heat the water
and seem like less hot water.
9, If you cannot find what is wrong, call the Sears Service
Center.
WATER IS TOO HOT
1
- The temperature adjustment dial may be set too high.
See the "Temperature Adjustment" section.
NOTE: A period of fime is necessary after an adjust
ment
has
been
made
for
the
water
temperature
to
reach the new temperature setting.
2
if lower temperature settings will not lower the water
temperature, call the Sears Service Center.
Should
overheating
occur
or
the
gas
supply
fail
to
shut off, turn "OFF" the manual gas contro! valve tp
the appliance.
19