Print approval, Flexlock fls radius roof edge, Material – Flex FLS Roof Edge User Manual
Page 5: Quantities, Flexlock fls radius roof edge dimensions, Ckd by: sak
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
![background image](/manuals/718021/5/background.png)
FLEXLOCK FLS RADIUS ROOF EDGE
FULLY ADHERED OR MECHANICALLY ATTACHED SINGLE-PLY VERSION
IMPORTANT!
MUST INDICATE PROPER RADIUS CONDITION BY
CIRCLING APPROPRIATE OUTSIDE FACE
PROVIDING A RADIUS
THE RADIUS MAY BE PROVIDED
IN ONE OF TWO METHODS:
1.) THE ACTUAL KNOWN RADIUS IS
ROOF LINE
(SMALLEST
RADIUS
ALLOWED
IS12'-0" [3.65 m])
OR
2.) FIELD CONDITION MEASUREMENTS
NOTE: REFER TO ATTACHED WORKSHEET
(MAX. RISE ALLOWED
IS 1 1/8" [29 mm] ON
36" CHORD)
OUTSIDE
FACE
RADIUS
(PROVIDED BY APPROVER
PER DETAIL A)
TOP
VIEW
FASCIA
MIDPOINT OF
STRAIGHT EDGE
--------- --------- 36"
(914 mm)
LENGTH OF
STRAIGHT EDGE
NOTE: CHECK MEASUREMENTS ALONG ENTIRE RADIUS.
DETAIL A
INDICATES AREAS THAT WILL BE SLIT AS
NEEDED TO ACCOMODATE RADIUS
FLEXLOCK FLS RADIUS ROOF EDGE DIMENSIONS
PRODUCT
H
X
NAILER
ID. NO.
DIM
DIM
COVERAGE
□ FA-50
5 1/4" (133 mm)
2 7/8"
(73 mm)
1 NAILER
□ FA-65
6 3/4" (171mm)
4 3/8"
(111 mm)
2 NAILERS
□ FA-80
8 1/4" (210 mm)
5 7/8"
(149 mm)
3 NAILERS
□ FA-95
9 3/4" (248 mm)
7 3/8"
(187 mm)
4 NAILERS
□ FA-110
11 1/4" (286 mm)
8 7/8"
(225 mm)
5 NAILERS
□ FA-125
12 3/4" (324 mm)
10 3/8 ' (264 mm)
6 NAILERS
Fabrication will proceed only after receipt of
signed print approval.
Print Approval:
Architect and/or contractor shall verify all
dimensions, sizes and quantities. All
products to be installed in strict accordance
with Flex's printed instructions.
Approved by:
Date:
_____
MATERIAL:
*Oil canning can
___ 24 Ga. (.65 mm) Galv. Steel*
occur on larger face
.040" (1.01 mm) Alum.*
heights. Recommend
.050" (1.27 mm) or .063"
(1.60 mm) for face
heights above
8X" (210 mm)
___ .050" (1.27 mm) Alum.
___ .063" (1.60 mm) Alum.
OTHER
Color;
Finish:
QUANTITIES
Lineal Feet 12'-0" (3.65 m) Lengths
PROJECT:
ARCHITECT:
ROOFING CONTRACTOR:
REPRESENTATIVE/DISTRIBUTOR:
Customer Service:
Phone: 800-969^0108
Fax:610-916-9501
DATE: 12/13/10
DRN BY: JJC
CKD BY: SAK
SHT# OF
DWG# 28010-11353
D
print approval
48
p: 800-969-0108
f: 610-916-9501