Fig. 1 — dimensions, O r~j, Evap – Carrier 50AH024-060 User Manual
Page 2: Table 1 — physical data
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
r-5 MIN FOR
REMOVAL OF
PANEL
BOTTOM ACCESS'
PANEL (COND FAN
MOTOR
a
BLOWER, COND
COIL WASHDOWN)
CONDENSER COIL
WASHDOWN DRAIN 5
CORNER D
4'-o"
o
FPT
DIMENSIONS (ft-in.)
0'-4"-
I I
r - i -
I
I
I
I
I I
1
> \
1
1 i r -
i i i
1 1 1
" " i _ _ _ _ j i
_ _ _
1
°
/-~>COMPR !
{ '
CORNER C
1- —,
1
2-
1
-2-4"-
TgDIA (TYP 8 PLACES)
RIGGING HOLES
o r~j--1 --
CONTROL BOX
FIELD POWER SUPPLY
JUNCTION BOX
CORNERA
r-5" MIN FOR REMOVAL
\___ , OF PANEL
^EVAP
r 'COIL
■CORNER B
—0'-4"
EVAP COIL
ACCESS PANEL
UNIT
50AH
A
B
C
D
E
024
2-5
2-1%
1- 4%
1-2
1-1
036
2-4%
2-2
1- 4%
1-2
1-1
048
2-5
2-3
1-11%
1-8%
1-7%
060
2-4%
2-2%
1-11%
1-8%
1-7%
COND SECT.
ACCESS PANEL
0'-5"
I "DIA HOLE FIELD
CONTROL WIRING
coMPR
a
CONTROLS
ACCESS
PANEL
Fig. 1 — Dimensions
FILTER
CONDENSATE DRAINS (2)
0'-3"MIN FOR P-TRAP
BOTTOM ACCESS
PANEL(EVAR
■FAN MOTOR a
BLOWER, EVAR
COIL a
CONDENSATE
PAN)
FPT
- Center of Gravity
- Direction of Airflow
Table 1 — Physical Data
UNIT 50AH
024
036
048
060
SHIPPING WEIGHT (lbs) (Note 1)
600
620
700
710
OPERATING WEIGHT (lbs)
Base Unit
480
500
580
590
OPERATING CHARGE (lbs) (Note 2)
56
5.5
80
76
Refrigerant
R-22
COMPRESSOR — TYPE
Hermetic
Quantlty...Model
(1) AB5524H
(1). AV5535H*
(1).. P46
(1)...P60
Oil (oz)
32
32
76
76
HPS Setting (psig)
Cutout
426 ± 7
Reset
320 ± 20
LPS Setting (psig)
Cutout
27 ± 4
Reset
67 ± 7
CONDENSATE CONNECTION
Size (in.)...Type
Condensate Drain
%...FPT
CONDENSER FAN
Centrifugal — Direct-Drive
Centrifugal — Belt Drive
Nominal Cfm
1350
2250
2450
Maximum Rpm
1100
1500
Blower Size On.)
12 X 6
12
X
9
Pulley Pitch Diameter (in.)
Blower
None
60
60
60
Motor (Variable)
None
2 4-3 4
1 9-2 9
2 4-3 4
Motor Hp
%
%
1 0
1 5
Motor Rpm
825
1725
1725
1725
EVAPORATOR FAN
Centrifugal — Direct-Drive
Nominal Cfm
800
1200
1600
2000
Maximum Rpm
1100
1150
1050
1050
Blower Size (in.)
10
X
5
10
X 6
10
X 8
10
X 8
Motor Hp
Vs
Vi
%
%
CONDENSER COIL
Copper Tubes — Aluminum Fins
Size (L
X
H) (in.)
40
X
15
40
X
22
Number of Rows...Fins/in.
4...13.6
EVAPORATOR COIL
Copper Tubes — Aluminum Fins
Size (L
X
H) (in.)
34
X
15
34
X
22
Number of Rows...Fins/in.
4...14.4
INDOOR AIR FILTERS
Factory-Supplied Cleanable Type
Number...Size (in.)
(1) .1
CFM — Cubic Feet per Minute
FPT — Female Pipe Thread
PSIG — Pounds per Square Inch Gage
RPM — Revolutions per Minute
'Three-phase units use (1) AV5535E compressor
NOTES:
1 Shipping weights include base unit plus packaging
2. If components are to be split, additional refrigerant will be needed Refer to charging
charts found on page 5 and
6
3 If components are to be split, the maximum length of refrigerant tubing to be used is
75 ft, assuming components will be installed in same horizontal plane If components
are not to be installed in same horizonal plane, contact Carrier, Syracuse for more
information For additional piping information, refer to Carrier System Design Manual,
Part 3