User manual - optima ups 1k-3k (english), Features by products family, Safety / quality / performance standards – XMART Optima 3K-HB User Manual
Page 4
![background image](/manuals/716252/4/background.png)
USER MANUAL - OPTIMA UPS 1K-3K (ENGLISH)
_________________________________________________________________________________________________________________________________
www.xmart-ups.com
1406-OPTIMA
1K-3K
- 4
FEATURES BY PRODUCTS FAMILY
UPS
UPS
INVERTER INTERNAL INVERTER
EXBATT
PROGR.
FAMILY
TECH.
TYPE
BATT QTY
VOLTAGE
OPTION
ECO
EPO
FC
OUTLETS
OPTIMA 1K
ONLINE
(HBCN) 3 36VDC YES YES YES YES YES
OPTIMA 1.5K
ONLINE
(HBCN) 3 36VDC YES YES YES YES YES
OPTIMA 2K
ONLINE
(HBCN) 6 72VDC YES YES YES YES YES
OPTIMA 3K
ONLINE
(HBCN) 6 72VDC YES YES YES YES YES
OPTIMA 1KF-HB ONLINE
(HBCN) 2 24VDC YES YES NO YES NO
OPTIMA 2KF-HB ONLINE
(HBCN) 4 48VDC YES YES NO YES NO
OPTIMA 3KF-HB ONLINE
(HBCN) 6 72VDC YES YES NO YES NO
OPTIMA 1KF
ONLINE
(FB) 2
24VDC
YES
YES
NO
NO NO
OPTIMA 2KF
ONLINE
(FB) 4
48VDC
YES
YES
NO
NO NO
OPTIMA 3KF
ONLINE
(FB) 6
72VDC
YES
YES
NO
NO NO
OPTIMA 1KF-CN ONLINE
(FBCN) 2 24VDC
YES YES NO NO NO
OPTIMA 2KF-CN ONLINE
(FBCN) 4 48VDC
YES YES NO NO NO
OPTIMA 3KF-CN ONLINE
(FBCN) 6 72VDC
YES YES NO NO NO
Comments;
HBCN: Half Bridge Common Neutral. Inverter with half bridge topology. Output neutral is connected to input neutral in normal mode.
FB:
Full Bridge. Inverter with full bridge topology. Output neutral is not connected to input neutral.
FBCN:
Full Bridge Common Neutral: Inverter with full bridge topology. Output neutral is connected to input neutral in normal mode.
ECO:
Economy or Ecological Mode. Optional mode that generates energy saving compared with normal mode.
EPO:
Emergency Power OFF: It is a function than shutdown UPS outlets when activated
FC:
Frequency Conversion Function: It allows UPS to generate an output frequency different than input frequency.
1. SAFETY / QUALITY / PERFORMANCE STANDARDS
SAFETY - LOW VOLTAGE DIRECTIVE (2006/95/EC)
UPS Part 1-1: General & Safety UPS in accessible areas
IEC/EN 62040-1
ELECTROMAGNETIC COMPATIBILITY - EMC DIRECTIVE (2004/108/EC)
UPS, Part 2, Electromagnetic Compatibility:
IEC/EN 62040-2
Low Freq. Conducted Disturbances & Signals:
IEC/EN 61000-2-2
Electrostatic discharge immunity Test:
IEC/EN 61000-4-2 (Level 3)
Radiated radio Frequency immunity:
IEC/EN 61000-4-3 (Level 3)
Electrical Fast Transient / burst immunity:
IEC/EN 61000-4-4 (Level 4)
Surge immunity:
IEC/EN 61000-4-5 (Level 4)
Conducted Immunity:
IEC/EN 61000-4-6
Power frequency magnetic field immunity:
IEC/EN 61000-4-8
Voltage Dips, Short Interruptions & Voltage Variations Immunity:
IEC/EN 61000-4-11
UPS Part 3: Methods of operation, specifications and test requirement
IEC/EN 62040-3
IT Equipments. SAFETY. Part 1: General Requirements
IEC/EN 60950-1
IP PROTECTION
IP20 (static)
QUALITY MANAGEMENT:
Manufactured under: ISO 9001 :
2000
ENVIRONMENTAL MANAGEMENT:
Manufactured under: ISO 14001 :
2004
Any modification made by user or operator may affect compliance of the safety and performance certifications listed above. UPS manufacturer is not
responsible of any modification made on the product or its accessories after it is manufactured.
This product is designed to operate in domestic and commercial environment.