beautypg.com

User manual - optima ups 1k-3k (english), Features by products family, Safety / quality / performance standards – XMART Optima 3K-HB User Manual

Page 4

background image

USER MANUAL - OPTIMA UPS 1K-3K (ENGLISH)

_________________________________________________________________________________________________________________________________

www.xmart-ups.com

1406-OPTIMA

1K-3K

- 4

FEATURES BY PRODUCTS FAMILY

UPS

UPS

INVERTER INTERNAL INVERTER

EXBATT

PROGR.

FAMILY

TECH.

TYPE

BATT QTY

VOLTAGE

OPTION

ECO

EPO

FC

OUTLETS

OPTIMA 1K

ONLINE

(HBCN) 3 36VDC YES YES YES YES YES

OPTIMA 1.5K

ONLINE

(HBCN) 3 36VDC YES YES YES YES YES

OPTIMA 2K

ONLINE

(HBCN) 6 72VDC YES YES YES YES YES

OPTIMA 3K

ONLINE

(HBCN) 6 72VDC YES YES YES YES YES

OPTIMA 1KF-HB ONLINE

(HBCN) 2 24VDC YES YES NO YES NO

OPTIMA 2KF-HB ONLINE

(HBCN) 4 48VDC YES YES NO YES NO

OPTIMA 3KF-HB ONLINE

(HBCN) 6 72VDC YES YES NO YES NO

OPTIMA 1KF

ONLINE

(FB) 2

24VDC

YES

YES

NO

NO NO

OPTIMA 2KF

ONLINE

(FB) 4

48VDC

YES

YES

NO

NO NO

OPTIMA 3KF

ONLINE

(FB) 6

72VDC

YES

YES

NO

NO NO

OPTIMA 1KF-CN ONLINE

(FBCN) 2 24VDC

YES YES NO NO NO

OPTIMA 2KF-CN ONLINE

(FBCN) 4 48VDC

YES YES NO NO NO

OPTIMA 3KF-CN ONLINE

(FBCN) 6 72VDC

YES YES NO NO NO

Comments;
HBCN: Half Bridge Common Neutral. Inverter with half bridge topology. Output neutral is connected to input neutral in normal mode.
FB:

Full Bridge. Inverter with full bridge topology. Output neutral is not connected to input neutral.

FBCN:

Full Bridge Common Neutral: Inverter with full bridge topology. Output neutral is connected to input neutral in normal mode.

ECO:

Economy or Ecological Mode. Optional mode that generates energy saving compared with normal mode.

EPO:

Emergency Power OFF: It is a function than shutdown UPS outlets when activated

FC:

Frequency Conversion Function: It allows UPS to generate an output frequency different than input frequency.

1. SAFETY / QUALITY / PERFORMANCE STANDARDS

SAFETY - LOW VOLTAGE DIRECTIVE (2006/95/EC)
UPS Part 1-1: General & Safety UPS in accessible areas

IEC/EN 62040-1

ELECTROMAGNETIC COMPATIBILITY - EMC DIRECTIVE (2004/108/EC)
UPS, Part 2, Electromagnetic Compatibility:

IEC/EN 62040-2

Low Freq. Conducted Disturbances & Signals:

IEC/EN 61000-2-2

Electrostatic discharge immunity Test:

IEC/EN 61000-4-2 (Level 3)

Radiated radio Frequency immunity:

IEC/EN 61000-4-3 (Level 3)

Electrical Fast Transient / burst immunity:

IEC/EN 61000-4-4 (Level 4)

Surge immunity:

IEC/EN 61000-4-5 (Level 4)

Conducted Immunity:

IEC/EN 61000-4-6

Power frequency magnetic field immunity:

IEC/EN 61000-4-8

Voltage Dips, Short Interruptions & Voltage Variations Immunity:

IEC/EN 61000-4-11

UPS Part 3: Methods of operation, specifications and test requirement

IEC/EN 62040-3

IT Equipments. SAFETY. Part 1: General Requirements

IEC/EN 60950-1

IP PROTECTION

IP20 (static)

QUALITY MANAGEMENT:

Manufactured under: ISO 9001 :

2000

ENVIRONMENTAL MANAGEMENT:

Manufactured under: ISO 14001 :

2004

Any modification made by user or operator may affect compliance of the safety and performance certifications listed above. UPS manufacturer is not
responsible of any modification made on the product or its accessories after it is manufactured.
This product is designed to operate in domestic and commercial environment.

This manual is related to the following products: