4030-00

60706-50

ENGINE CONTROL MODULE (DSE 7310 Series)

The DSE 7310 Series control modules provide integrated engine

and generator set control, protection and metering in a single

package. Microprocessor based technology allows for exact

measurement, set point adjustment, and timing functions. Front

panel controls and indicators enable quick and simple operation.

Fully configurable via PC software, allows units to be easily

customized for each application. Includes selected front panel

programming for on site changes. A wide temperature-range

liquid crystal display (132 x 64) with backlighting can be viewed

under a wide range of ambient light and temperature conditions.

FEATURES

DSE 7310 Control Modules have the following features:

Local and Remote Generator Control

Engine and Generator Protection

CAN Bus compatible

Programmable Logic

Five-key Menu Navigation

Engine Exercise Mode

Automatic Transfer Switch Control (Mains Failure)

User Selectable RS232 & RS485 (Remote Operation)

FUNCTIONS

DSE 7310 Series Control Modules perform the following

protection and metering functions:

Generator Protection and Metering

Generator protection includes over voltage, under voltage,

under frequency, over frequency and overload protection. Each

generator protection function has an adjustable pickup and time

delay setting. Metered generator parameters include voltage,

current, real power (watts), power factor (PF)

Engine Protection and Metering

Engine protection features include oil pressure and coolant

temperature monitoring, over crank protection, ECU specific

protection elements, and diagnostic reporting.

Metered engine parameters include, oil pressure, coolant

temperature, battery voltage, speed, engine load, coolant level

(from ECU), ECU specific parameters, and run-time statistics.

** NOTICE **

These units will automatically transfer if a power outage occurs

while running in an exercise mode.

SPECIFICATIONS

MODEL

WATTS VOLTS

AMP

HZ

PH RPM

PSS1-3

1,000 10/40

89.0*

60

1

1800

PSS1-4

,000 10/08

76.4**

60

3

1800

PSS1-17 ,000 10/40

66.**

60

3

1800

PSS1-18 5,000 77/480

37.6**

60

3

1800

PSS30-3

30,000 10/40

15.0*

60

1

1800

PSS30-4

30,000 10/08

104.**

60

3

1800

PSS30-17 30,000 10/40

90.3**

60

3

1800

PSS30-18 30,000 77/480

45.1**

60

3

1800

PSS40-3

40,000 10/40

166.7*

60

1

1800

PSS40-4

40,000 10/08

138.9**

60

3

1800

PSS40-17 40,000 10/40

10.4**

60

3

1800

PSS40-18 40,000 77/480

60.**

60

3

1800

*Unity Power Factor - Derate 3.5% per 1000 feet elevation above

sea level.

**Power Factor .8 - Derate 3.5% per 1000 feet elevation above

sea level.

FUEL CONSUMPTION

NG

LP VAPOR

(1,000 BTU/CU FT) (2,520 BTU/CU FT)

MODEL CF/

HR

BTU/HR

#/HR

GAL/

HR

CF/

HR

BTU/HR

PSS1

340 340,000

16.3

3.9

136.9 344.983

PSS30

43 43,000

0.4

4.9

17

44.049

PSS40 499 498,907

5.0

5.9

10 541.01

L.P. TANK SIZING

Minimum required L.P. Tank size for L.P. Vapor withdrawal

operating at various outside temperatures given in degrees

Fahrenheit (Celsius)

TANK TEMPERATURE

MODEL 60 F(16 C) 30 F(0 C) 0 F(-18 C) -20 F(-29 C)
PSS1

160 Gal

300 Gal

1000 Gal*

000 Gal*

PSS30

160 Gal

300 Gal

1000 Gal*

000 Gal*

PSS40 50 Gal.

500 Gal. 1000 Gal.*

000 Gal.*

*Recommend liquid withdrawal at these temperatures.