5
4030-00
60706-50
ENGINE CONTROL MODULE (DSE 7310 Series)
The DSE 7310 Series control modules provide integrated engine
and generator set control, protection and metering in a single
package. Microprocessor based technology allows for exact
measurement, set point adjustment, and timing functions. Front
panel controls and indicators enable quick and simple operation.
Fully configurable via PC software, allows units to be easily
customized for each application. Includes selected front panel
programming for on site changes. A wide temperature-range
liquid crystal display (132 x 64) with backlighting can be viewed
under a wide range of ambient light and temperature conditions.
FEATURES
DSE 7310 Control Modules have the following features:
Local and Remote Generator Control
Engine and Generator Protection
CAN Bus compatible
Programmable Logic
Five-key Menu Navigation
Engine Exercise Mode
Automatic Transfer Switch Control (Mains Failure)
User Selectable RS232 & RS485 (Remote Operation)
FUNCTIONS
DSE 7310 Series Control Modules perform the following
protection and metering functions:
Generator Protection and Metering
Generator protection includes over voltage, under voltage,
under frequency, over frequency and overload protection. Each
generator protection function has an adjustable pickup and time
delay setting. Metered generator parameters include voltage,
current, real power (watts), power factor (PF)
Engine Protection and Metering
Engine protection features include oil pressure and coolant
temperature monitoring, over crank protection, ECU specific
protection elements, and diagnostic reporting.
Metered engine parameters include, oil pressure, coolant
temperature, battery voltage, speed, engine load, coolant level
(from ECU), ECU specific parameters, and run-time statistics.
** NOTICE **
These units will automatically transfer if a power outage occurs
while running in an exercise mode.
SPECIFICATIONS
MODEL
WATTS VOLTS
AMP
HZ
PH RPM
PSS1-3
1,000 10/40
89.0*
60
1
1800
PSS1-4
,000 10/08
76.4**
60
3
1800
PSS1-17 ,000 10/40
66.**
60
3
1800
PSS1-18 5,000 77/480
37.6**
60
3
1800
PSS30-3
30,000 10/40
15.0*
60
1
1800
PSS30-4
30,000 10/08
104.**
60
3
1800
PSS30-17 30,000 10/40
90.3**
60
3
1800
PSS30-18 30,000 77/480
45.1**
60
3
1800
PSS40-3
40,000 10/40
166.7*
60
1
1800
PSS40-4
40,000 10/08
138.9**
60
3
1800
PSS40-17 40,000 10/40
10.4**
60
3
1800
PSS40-18 40,000 77/480
60.**
60
3
1800
*Unity Power Factor - Derate 3.5% per 1000 feet elevation above
sea level.
**Power Factor .8 - Derate 3.5% per 1000 feet elevation above
sea level.
FUEL CONSUMPTION
NG
LP VAPOR
(1,000 BTU/CU FT) (2,520 BTU/CU FT)
MODEL CF/
HR
BTU/HR
#/HR
GAL/
HR
CF/
HR
BTU/HR
PSS1
340 340,000
16.3
3.9
136.9 344.983
PSS30
43 43,000
0.4
4.9
17
44.049
PSS40 499 498,907
5.0
5.9
10 541.01
L.P. TANK SIZING
Minimum required L.P. Tank size for L.P. Vapor withdrawal
operating at various outside temperatures given in degrees
Fahrenheit (Celsius)
TANK TEMPERATURE
MODEL 60 F(16 C) 30 F(0 C) 0 F(-18 C) -20 F(-29 C)
PSS1
160 Gal
300 Gal
1000 Gal*
000 Gal*
PSS30
160 Gal
300 Gal
1000 Gal*
000 Gal*
PSS40 50 Gal.
500 Gal. 1000 Gal.*
000 Gal.*
*Recommend liquid withdrawal at these temperatures.