Description and specifications, System description – USL CMSA-100 User Manual
Page 7
CMSA-100 Manual v131212
Page 7
Option – 1
Option – 2
Option – 3 ON
Option – 3 OFF
Preshow – ON
Preshow - OFF
5.
System Description
Output Relays (Solid State)
The CMSA-100 has 10 isolated solid-state relays with momentary outputs. These outputs
are rated for 24V AC/DC at 150 mA.
Output Relays (Power)
The CMSA-100 provides two independent contact relay outputs. They are rated for 240
VAC at 10 A. These relays are configurable to be momentary or latching. Each relay
consists of a common, normally open, and normally closed contact. (COM, NO, NC)
Inputs
There are two inputs on the CMSA-100 designed for contact closure inputs.
Interface to CMS-2200
An RJ45 connector with a standard Cat-5 cable is used as the interface to the CMS-2200.
This input is NOT Ethernet and will not function if plugged into Ethernet equipment,
switches or routers. This interface was specifically designed to be used between the
CMSA-100 and the CMS-2200.
Power Supply
The 12VDC, 1.5A power supply provided with the CMSA-100 comes with multiple adapters
for international use. Select the appropriate adapter and install it on the power supply.
The power source must be 100 – 240 VAC, 50 – 60 Hz.