Setup screens, Units, Time – TruTrak EMS BU (8300-065) User Manual
Page 6
TruTrak Flight Systems
4
EMS Installation Manual
JUNE 2009
8300-065 Rev D
SETUP SCREENS
INFO, UNITS, TIME, CONFIG, GAUGES, CALIB
To enter the setup screen the right
knob must be pressed and held until
the SETUP shows then press and
release the button below SETUP
before releasing the right knob.
Rotate the right knob to step to the
next page.
Press and release the right knob
[EXIT] to step back a page or to
return to the main screens.
INFO
Displays serial numbers and software version and model type of all
units connected to the TruTrak communication wires (TCB-A, TCB-
B).
Exit by press and release of left knob.
UNITS
BARO, IN HG or MBAR
DIST, NM, MI or KM
PRESS, PSI, IN HG or KPA
MANIFLD, IN HG or MMHG
TEMP, F or C
VOLUME, GALLON or LITER
These pages will allow the setting of
UNITS of Measure for the different
display readouts listed.
Example: Press and release BARO to select IN HG or
MBAR
as shown.
TIME
OIL, TZ, ZULU, DATE
Pressing the OIL button will reset the OIL, TRIP, & LEG timers.
LEG timer will reset with zero oil pressure for @ 5 min.
TRIP is reset with button.
The TZ (time zone) button sets your time zone by +/- from GMT
(Standard Central TZ = -6).
Set ZULU time with this button.(GMT)
Set the DATE with this button. The next screen allows the selection
of MONTH, DAY, and YEAR. Rotate the right knob to change
setting.