Edm function / fire wall – TruTrak EMS BU (8300-065) User Manual
Page 21
TruTrak Flight Systems
19
EMS Installation Manual
JUNE 2009
8300-065 Rev D
J3 Pin
EDM Function / Fire Wall
NOT NINE CYL
NN OPTION
1 - CHT 1 J Type
RED
2 - CHT 2 J Type
RED
3 - CHT 3 J Type
RED
4 - CHT 4 J Type
RED
5 - CHT 5 J Type
RED
6 - CHT 6 J Type
RED
7 NO CONNECTION
8 + EGT 1 K type
YELLOW
9 + EGT 2 K type
YELLOW
10 + EGT 3 K type
YELLOW
11 + EGT 4 K type
YELLOW
12 + EGT 5 K type
YELLOW
13 + EGT 6 K type
YELLOW
14 + CHT 1 J Type
WHITE
15 + CHT 2 J Type
WHITE
16 + CHT 3 J Type
WHITE
17 + CHT 4 J Type
WHITE
18 + CHT 5 J Type
WHITE
19 + CHT 6 J Type
WHITE
20 - EGT 1 K type
RED
21 - EGT 2 K type
RED
22 - EGT 3 K type
RED
23 - EGT 4 K type
RED
24 - EGT 5 K type
RED
25 - EGT 6 K type
RED
J2 Pin
EDM Function / Fire wall
Notes
1 Sensor
Ground
Sensor use only
2 TACH
3 Fuel
Flow
4 OAT
Thermister
5 Fuel
Pressure
6 OIL pressure Sensor (Resistive type)
Factory setup only
7 CHT 2 Thermister or Second OAT sensor (CARB TEMP)
8 Sensor 12 volt supply
Sensor use only
9 Sensor 12 volt supply
Sensor use only
10 Sensor 12 volt supply
Sensor use only
11 Sensor
Ground
Sensor use only
12 Sensor
Ground
Sensor use only
13 Sensor
Ground
Sensor use only
14 Sensor 5 volt supply
Sensor use only
15 Sensor 5 volt supply
Sensor use only
16 Current
Transducer
17 Not used at this time
18 Oil Temperature Thermister
19 CHT
1
Thermister
20 Oil
Pressure
21 Not used at this time
22 - EGT 1 RED K type / # Nine EGT
23 + EGT 1 YELLOW K type / # Nine EGT
24 - EGT 2 RED K type / # Nine CHT
25 + EGT 2 YELLOW K type / # Nine CHT