Phase III

®

6

Installation

Water Hammer

Dishwashers, clothes washers and fast-closing pos-
itive shut-off valves incorporated in the system all
contribute to creating water shock. Install a water
hammer arrester to prevent damage to pipes and
appliances. See device manufacturer’s instructions
for application and installation.

Water hammering within the domestic pip-
ing system can cause premature failure of
the inner tank of the water heater. This type
of failure is NOT
covered under warranty.

Vacuum Breaker

Installing a vacuum breaker on the domestic cold
water outlet will prevent damage to the inner tank
if a negative pressure is developed in the domestic
supply line. See manufacturer’s instructions for
application and installation of the vacuum breaker.

General Piping

For domestic water piping diagrams, see page 8
thru 10.

See pages 11 through 14 for:

- Boiler water piping

- Multiple water heater domestic and boiler

piping.

See Chart 1 for domestic and boiler piping
connections.

All plumbing must meet or exceed all local,
state and national plumbing codes.

Use pipe dope or tape suitable for potable
water systems.

Use isolation valves to isolate system components.

Domestic Piping

Union on domestic hot water outlet should be
piped at a higher elevation than domestic water
drain valve. This will make draining the water
heater easier.

Install unions for easy removal of water heater.
Use dielectric unions or couplings to protect

NOTICE

Chart 1

Connections - NPT

Recirculation Dip Tube

Draining Dip Tube

Recommended

Water Heater

Domestic

Boiler Water

Auxiliary

Length

Diameter

Length

Diameter

Minimum

Model

Water

Supply/

Connection

inches

inches

inches

inches

Boiler Piping

Inlet/Outlet

Return

Diameter (inches)

TR-20

3/4

1

3/4

34

3/4

34

3/4

1

TR-30

3/4

1

3/4

43

3/4

43

3/4

1

TR-36

3/4

1

3/4

52

3/4

52

3/4

1

TR-45

1

1 1/4

3/4

25

3/4

47

3/4

1 1/4

TR-60

1

1 1/4

1

25

1

54

1

1 1/4

TR-80

1 1/2

2

1 1/2

25

1 1/2

48

1 1/2

2

TR-100

1 1/2

2

1 1/2

32

1 1/2

61

1 1/2

2

TR-120

1 1/2

2

1 1/2

32

1 1/2

61

1 1/2

2

SMART 20

3/4

1

3/4

23.5

3/4

23.5

3/4

1

SMART 30

3/4

1

3/4

34

3/4

34

3/4

1

SMART 40

3/4

1

3/4

43

3/4

43

3/4

1

SMART 50

3/4

1 1/4

3/4

25

3/4

52

3/4

1 1/4

SMART 60

3/4

1 1/4

3/4

34

3/4

62

3/4

1 1/4

SMART 80

1 1/2

1 1/2

1 1/2

25

1 1/2

48

1 1/2

1 1/2

SMART 100

1 1/2

1 1/2

1 1/2

32

1 1/2

61

1 1/2

1 1/2

This manual is related to the following products: