Installation guide, For linear shower pan recessed into concrete, Step 12 – Trending Accessibility Transitional & modern linear fusion shower pan recessed into concrete User Manual
Page 5: Step 9, Step 11, Step 10
Installation Guide
www.trendingaccessibility.com
5
for linear shower pan recessed into concrete
Step 9
If the Fusion Pan is above the level of the floor, use
a screed bed to raise the floor.
Check that the Linear Fusion Pan is level on all four
sides.
Fill in any gaps around the perimeter of the pan over
1/8” with latex or acrylic caulk.
Do not use 100% silicone.
Step 12
Begin taping the wetroom floor at the interior corners
of the Linear Fusion Pan using the corner pieces of
the crack isolation tape provided. Using a paint brush
or trowel, slather liquid waterproofing into corner,
press piece into place, then apply liquid waterproof-
ing on top. Make sure to smooth out any creases.
Repeat for additional corners.
Step 11
You will now begin waterproofing the wet room.
BEST PRACTICE: To achieve the best results, we
recommend waterproofing the whole room.
Minimum requirements, shown in these instruc-
tions, show you that you only have to waterproof
the shower zone, which is 6 ½ feet high and about
2 feet outside of the showering area.
Materials needed for wet room waterproofing.
Step 10
Make your final connections to the drain. Make
sure connection is snug but do not over tighten.