4. SPECIFICATIONS
133-21-947-60
URL: http://www.toa.jp/
Mount the substation to the YC-302 2-gang electrical box mounted in the wall.
Notes
• When using the PA paging function, keep the station as far away from
the PA paging speaker as possible to avoid acoustic feedback.
• When installing the RS-470 at outdoor or locations where it gets wet
with water, tightly seal the panel edges. Besides, provide a weep hole
at the underside of the mounting box to permit water to drain off.
Machine screw M4 x 25
(accessory)
Note: This figure represents the RS-460/470.
YC-302
2-gang electrical box
(option)
Substation
Wall surface
Seal the panel edges.
RS-470's front panel
[In-wall mounting using an electrical box]
Accessory screws
The RS-450, RS-460, and RS-470 come with 2
types of screws: M4 x 25 and UNC No. 6-32 x 18.
For the electrical box provided with unified
threads, use the UNC No. 6-32 x 18.
Model No.
RS-450
RS-460
RS-470
Call Button
Momentary (Emergency call: Press twice within 400 ms.)
Rated Input
1 W
Internal Speaker
Cone-type
Internal Mic
Electret condenser type
Wiring
Twisted pair cables (2-pair)
Transmission Range
1000 m/ø0.5 mm (AWG24), 1500 m/ø0.65 mm (AWG22),
2000 m/ø0.9 mm (AWG19)
Operating Temperature
–10 to +50°C (Temperature range not to freeze the speaker and switch)
Housing Protection
-
BS EN62262: 2002: IK02 equivalent
Dust/Water Protection
-
IP54
Finish (Panel)
Stainless steel, hairline
(Call button)
Resin, black
Metal, silver
(Circuit board)
(RS-470 only) Weather-resistant coating
Dimensions (w)
120 mm
(h)
120 mm
(d)
41.5 mm
49.5 mm
Weight
510 g
540 g
550 g
Accessory
No. 6-32 UNC x 18 ... 4, Machine screw M4 x 25 ... 4
Applicable Box
2-gang electrical box: YC-302 (option)
Traceability Information for Europe (EMC directive 2004/108/EC)
Manufacturer:
TOA Corporation
7-2-1, Minatojima Nakamachi, Chuo-ku, Kobe, Hyogo,
Japan
Authorized representative:
TOA Electronics Europe GmbH
Suederstrasse 282, 20537 Hamburg,