beautypg.com

Installation specifications dimensional diagram – Toa C-BC100T User Manual

Page 2

background image

10 kg

Indoor and outdoor ceiling surfaces
(except those in shore and industrial
areas where the unit becomes
corroded, and those on the heights
exposed to strong winds)
Horizontal: 360°
Vertical: 60° (up) – 60° (down)
Stainless steel, off white
100 (W) x 295 (H) x 100 (D) mm
830 g
C-CH100 and C-CH100FH

Maximum Load
Weight
Installation Place

Adjustable Bracket
Head Angle
Finish
Dimensions
Weigh
Usable Housings

INSTALLATION

SPECIFICATIONS

DIMENSIONAL DIAGRAM

100

80

ш31.8

ш7

100

4-ш8.5

80

30

65

10

70

90

200

Note: The design and specifications are subject to change

without notice for improvement.

Housing mounting hole

1.

Using suitable nuts and
bolts, secure the bracket to
the ceiling at four places.

2.

Insert the supplied housing mounting
bolt into the mounting hole in the
housing top panel so that the bolt
protrudes about 3 mm.

3.

Push the bolt in the bracket's hole,
then pull the housing forward till the
bolt fits in the hole.

4.

Tighten the bolt to secure the
housing.

5.

Using another supplied housing
mounting bolt, secure the
housing to the bracket.

6.

Horizontal angle adjustment

Loosen four bolts. After
adjusting the horizontal angle,
retighten the bolts.

Safety wire fixing hole

Camera housing top panel

Unit: mm

7.

Vertical angle adjustment
Loosen two hexagonal M6 bolts
on the sides. After adjusting the
vertical angle, retighten the
bolts.

Housing mounting bolt
Hexagonal M6 bolt with captive
washer

Note: The vertical angle adjustment bolts are loosely set when the unit is shipped from the factory.

Be sure they are securely tightened after mounting the housing.

• Accessory

Housing mounting bolt ................................ 2 set

133-05-314-8B

URL: http://www.toa.jp/