Fieldpilot, Installation of engage/disengage switch, Install the valve control cable – TeeJet FieldPilot Install Ford Versatile 8x6-9x6 User Manual
Page 17
www.teejet.com
15
FieldPilot
®
10. installatiOn OF engage/disengage switch
Connect item
(A)
to the connector on the SCM harness labeled Remote Engage/Disengage. Install the push
button in a location that is easily accessible during operation of the machine. This switch
(A)
is not required
if the optional foot switch 32-04020 is used.
Figure 1-13: Engage/Disengage Switch
11. install the ValVe cOntrOl caBle
Connect the FieldPilot valve control cable
(E)
to the coils on the FieldPilot valve and route the cable into the
cab. Connect it to the SCM harness. Do not be concerned at this time about which connector is connected to
which solenoid coil.