Fieldpilot, Discarded hose connection point, Discarded hose connection point q r o – TeeJet FieldPilot Install Ford Versatile 8x6-9x6 User Manual
Page 13
www.teejet.com
11
FieldPilot
®
4. PrePare OrBital ValVe
Before installing any hoses, disconnect and discard the Pressure hose between the Pressure Relief Valve
and the Orbital P port. Disconnect the Tank hose from the T port of the orbital and install the
(R)
#16 Run
Tee to this port. Connect the
(Q)
adaptor fitting to the branch of the Tee. Reconnect the Tank hose to
the run of the Tee. Disconnect the hose from the L port. Install
(O)
#10 Run Tee to this port. Reconnect
the hose to the run of the Tee. Disconnect the hose from the R port. Install
(O)
#10 Run Tee to this port.
Reconnect the hose to the run of the Tee.
Note: Additional hose length for the L & R ports may need to be pulled up from the underside of the tractor.
Figure 1-7: Prepare Orbital Valve
Discarded Hose
Connection Point
Discarded Hose
Connection Point
Q
R
O