beautypg.com

Application quick start, On-board help window, Button functions system setup quick start – TeeJet Legacy 6000 Quick Start Guide User Manual

Page 2: Rate page, Map page

background image

Advance to
Next Step

After the Job has been named advance to
the ARM (Application Rate Management)
Launcher page. (Calibration, ARM Setup,
Job Report, and Product Setup)

Calibration

Calibration

Not required for each job. Follow
the Step-By-Step procedure. See
the L6K User Guide (P/N 98-
05067) for a more detailed
description.

ARM Setup
Job Report

ARM Setup

Job Report

OPTIONAL
ARM Setup and Job Report do not
require any settings to start appli-
cation.
ARM Setup - Data files
Job Report - Weather & Soil con-
ditions

Product Setup

Product
Setup

Favorite
Folder

Product Setup has mandatory set-
tings that must be completed for
application to begin. If more than
one product is in use select the
desired PCM or Channel and pro-
ceed through Product Setup.
Repeat Product Setup for each
PCM or Channel.

Density: If required for application
(granular) enter the product den-
sity

Cal Basis: When using a Cal
Table for Cal#’s select the heading
for the desired calibration #.

Straight Rate

Product: Select the Main product
to be applied. Scroll through the
list of products in the middle of the
screen or quickly locate the prod-
uct by entering the first few letters
of the product in the data entry
box.
Note: once a product has been
selected and used that product
can be found in the favorites
folder.

Rate A,B,C,D, & E: Up to five
rates can be entered. Only one is
required. These rates will be
selectable from the real-time
screen allowing the change of
rates on the go.

Variable Rate

Prescription: Use the UP/Down
arrows to select the desired pre-
scription map. The prescription
map must be located on the root
directory of the data card.

Layer: If using a multiproduct pre-
scription map each product will
need to be assigned a Layer.

Product: The product should
automatically be entered from the
prescription map.

Rate A,B,C,D, & E: Optional, rate
will be supplied from prescription
map

Step

Soft-Key

Description

Application Quick Start

Rate Page

Advance &
Save

Advance & Save out of product setup back to
the ARM Launcher page.

Start
Application

Press the Bullseye from the ARM Launcher
page. This will advance to the application
screen.

Soft-key

Button

Description

Select Rate

Press the Rate Selection button on
the left side of the screen and
select the desired rate. Repeat this
step for each product.

Straight Rate - (A-E)

Variable Rate - (VR)

Manual Mode - Manual

Straight rates and VR Prescription
maps are entered in Product
Setup.

Manual Mode

Manual mode can be used to prime a liquid
system and general trouble shooting. When
Manual Mode is selected + and - arrows will
appear on the Rate Page (right side). The
operator has full control of the control valve.

Up Arrow + : Should increase product at the
delivery point

Down Arrow - : Should Decrease product to
the delivery point.

Information
Pages

Use the Information Pages button to switch
between (3) information pages. For each
product there will be (3) pages.

Main Rate Page: Product name, Live Rate,
Speed, Total Accumulation, Product Remain-
ing, Area, and Monitor 1.

Second Rate Page: Product name, Target
Rate, Actual Rate, Distance, Monitors 2,3,4,
and Application width.

GPS Page: GPS coordinates, Speed, Course
on ground, Bounded Area.

Exit

The Exit soft-key. When pressed Fieldware
exits out of the application process and
returns to the ARM launcher page.

Nitrogen

150

OFF
A: 150
B: 160
C: 180
D: 200
E: 300
VR
Manual

Main Rate Page

Application Rate Selection
- Straight Rate
- Variable Rate (VR)
- Manual Mode

Information Pages

CAN Access

Re-Fill Initial Quantity

Alarms Off

OPTIONAL

Switch from Rate Page
to Map Page

Exit

Application Quick Start

Map Page

On-Board Help Window

Soft-key

Button

Description

Map Page

Use the BLUE arrow to switch between the
Information pages and the Map page.

Boundary

Mapping
Boundary

Select the boundary icon and then select
inner or outer and the side of the implement
the boundary will be drawn. When the opera-
tor is within 18 meters of the start point the
boundary will automatically close or push the
boundary icon and select close.

Select the
Guidance
Mode

From the Map page select the Guidance
Mode.

Straight-Line - Mark A-B

Headland - Curved guidance

Circle Pivot - Mark A-B

Ignore Headland - Apply headland to ignore
at later time

Exit

The Exit soft-key. When pressed Fieldware
exits out of the application process and
returns to the ARM launcher page.

Live Application Rate
Once rate is selected

Mapping Options

Exit

Switch from Rate
Page to Map Page

MAP Page

Use the On-Board help window

for information and functions of

the button highlighted.

Button Functions

System Setup Quick Start

Step

Soft-Key

Description

Start

Press the Bullseye from the Main Launcher
page. This will advance to Job Section.

No PC Card
Reset Type

RESET

None - No totals will be reset

Field Reset - This will reset the field area
and volume for all PCM’s

Total Reset - Will reset field area, volume,
and total area.

Using PC Card
Job Selection

There are two Job selection options.

New Job (operator must complete Product
Setup-----Product name & Rates)

New Job based on last Job settings. Opera-
tor does not have to complete Product Setup.
The system will use the previous product
name & rates. (Use if application has not
changed from previous job)

Using PC Card
Naming Job

There are three ways to name a Job

Auto-Name (Todays Date - Job #)

Manual Alpha Numeric entry. Use the Up/
Down arrows to select the character and use
the Left/Right to switch between characters.

USB Keyboard

Steps highlighted in yellow are the only steps required at the start of

each job if using a PC Card and the application has not changed.

Main Launcher Page

START

Mapper

System Tools

System Setup

Function Keys

Enter Key

Function Keys

Power On/Off

Escape

Arrow Keys

Brightness/Contrast

F6
F7

F8

F9

F10

F5

F1

F4

F3

F2