Application quick start, On-board help window, Button functions system setup quick start – TeeJet Legacy 6000 Quick Start Guide User Manual
Page 2: Rate page, Map page

Advance to
Next Step
After the Job has been named advance to
the ARM (Application Rate Management)
Launcher page. (Calibration, ARM Setup,
Job Report, and Product Setup)
Calibration
Calibration
Not required for each job. Follow
the Step-By-Step procedure. See
the L6K User Guide (P/N 98-
05067) for a more detailed
description.
ARM Setup
Job Report
ARM Setup
Job Report
OPTIONAL
ARM Setup and Job Report do not
require any settings to start appli-
cation.
ARM Setup - Data files
Job Report - Weather & Soil con-
ditions
Product Setup
Product
Setup
Favorite
Folder
Product Setup has mandatory set-
tings that must be completed for
application to begin. If more than
one product is in use select the
desired PCM or Channel and pro-
ceed through Product Setup.
Repeat Product Setup for each
PCM or Channel.
Density: If required for application
(granular) enter the product den-
sity
Cal Basis: When using a Cal
Table for Cal#’s select the heading
for the desired calibration #.
Straight Rate
Product: Select the Main product
to be applied. Scroll through the
list of products in the middle of the
screen or quickly locate the prod-
uct by entering the first few letters
of the product in the data entry
box.
Note: once a product has been
selected and used that product
can be found in the favorites
folder.
Rate A,B,C,D, & E: Up to five
rates can be entered. Only one is
required. These rates will be
selectable from the real-time
screen allowing the change of
rates on the go.
Variable Rate
Prescription: Use the UP/Down
arrows to select the desired pre-
scription map. The prescription
map must be located on the root
directory of the data card.
Layer: If using a multiproduct pre-
scription map each product will
need to be assigned a Layer.
Product: The product should
automatically be entered from the
prescription map.
Rate A,B,C,D, & E: Optional, rate
will be supplied from prescription
map
Step
Soft-Key
Description
Application Quick Start
Rate Page
Advance &
Save
Advance & Save out of product setup back to
the ARM Launcher page.
Start
Application
Press the Bullseye from the ARM Launcher
page. This will advance to the application
screen.
Soft-key
Button
Description
Select Rate
Press the Rate Selection button on
the left side of the screen and
select the desired rate. Repeat this
step for each product.
Straight Rate - (A-E)
Variable Rate - (VR)
Manual Mode - Manual
Straight rates and VR Prescription
maps are entered in Product
Setup.
Manual Mode
Manual mode can be used to prime a liquid
system and general trouble shooting. When
Manual Mode is selected + and - arrows will
appear on the Rate Page (right side). The
operator has full control of the control valve.
Up Arrow + : Should increase product at the
delivery point
Down Arrow - : Should Decrease product to
the delivery point.
Information
Pages
Use the Information Pages button to switch
between (3) information pages. For each
product there will be (3) pages.
Main Rate Page: Product name, Live Rate,
Speed, Total Accumulation, Product Remain-
ing, Area, and Monitor 1.
Second Rate Page: Product name, Target
Rate, Actual Rate, Distance, Monitors 2,3,4,
and Application width.
GPS Page: GPS coordinates, Speed, Course
on ground, Bounded Area.
Exit
The Exit soft-key. When pressed Fieldware
exits out of the application process and
returns to the ARM launcher page.
Nitrogen
150
OFF
A: 150
B: 160
C: 180
D: 200
E: 300
VR
Manual
Main Rate Page
Application Rate Selection
- Straight Rate
- Variable Rate (VR)
- Manual Mode
Information Pages
CAN Access
Re-Fill Initial Quantity
Alarms Off
OPTIONAL
Switch from Rate Page
to Map Page
Exit
Application Quick Start
Map Page
On-Board Help Window
Soft-key
Button
Description
Map Page
Use the BLUE arrow to switch between the
Information pages and the Map page.
Boundary
Mapping
Boundary
Select the boundary icon and then select
inner or outer and the side of the implement
the boundary will be drawn. When the opera-
tor is within 18 meters of the start point the
boundary will automatically close or push the
boundary icon and select close.
Select the
Guidance
Mode
From the Map page select the Guidance
Mode.
Straight-Line - Mark A-B
Headland - Curved guidance
Circle Pivot - Mark A-B
Ignore Headland - Apply headland to ignore
at later time
Exit
The Exit soft-key. When pressed Fieldware
exits out of the application process and
returns to the ARM launcher page.
Live Application Rate
Once rate is selected
Mapping Options
Exit
Switch from Rate
Page to Map Page
MAP Page
Use the On-Board help window
for information and functions of
the button highlighted.
Button Functions
System Setup Quick Start
Step
Soft-Key
Description
Start
Press the Bullseye from the Main Launcher
page. This will advance to Job Section.
No PC Card
Reset Type
RESET
None - No totals will be reset
Field Reset - This will reset the field area
and volume for all PCM’s
Total Reset - Will reset field area, volume,
and total area.
Using PC Card
Job Selection
There are two Job selection options.
New Job (operator must complete Product
Setup-----Product name & Rates)
New Job based on last Job settings. Opera-
tor does not have to complete Product Setup.
The system will use the previous product
name & rates. (Use if application has not
changed from previous job)
Using PC Card
Naming Job
There are three ways to name a Job
Auto-Name (Todays Date - Job #)
Manual Alpha Numeric entry. Use the Up/
Down arrows to select the character and use
the Left/Right to switch between characters.
USB Keyboard
Steps highlighted in yellow are the only steps required at the start of
each job if using a PC Card and the application has not changed.
Main Launcher Page
START
Mapper
System Tools
System Setup
Function Keys
Enter Key
Function Keys
Power On/Off
Escape
Arrow Keys
Brightness/Contrast
F6
F7
F8
F9
F10
F5
F1
F4
F3
F2