Centerline settings, Swath manager 5 & controller switch configuration, Swath man – TeeJet CenterLine with Swath Manager 5 User Manual
Page 2

Page 2 of 2
CenterLine Settings
•
The Swath Man setting is only available when Swath Manager 5 is detected.
•
When Swath Manger 5 is detected the Status setting is deactivated.
•
In Guidance Setup the Width setting is used for guidance only.
Swath Man
1. Select the desired %overlap (0%, 50%, 100%)
2. Enter the number of boom sections 1-5
3. Enter the width for each boom section
4. Set a delay in seconds. This will act as a look ahead to turn booms off and on when
entering and exiting an applied zone
Swath Manager 5 & Controller Switch Configuration
Figure 3: Swath Manager 5 Setup
Figure 4: Switch Positions
Width
Ahead
Antenna
NEXT
GPS Type
1HZ MSG
Alarm
To Start
Swath Man
% Overlap
Sections
Width 1
Delay
NEXT
To Start
0%
50%
100%
GUIDANCE
SETUP
SWITCH POSITIONS
Swath Manager 5
System
*
original Master
Sw
itch
**
SM
5 Master
Sw
itch
SM
5 Bo
om Sw
itches
E
ngage / Disengage
Swath Manager 5 Auto
Boom mode
ON
OFF
ON
ON
Engage
Swath Manager 5
Manual Boom mode
ON
OFF
ON
ON
Disengage
For Individual boom section
control use SM5 boom switches
*
TeeJet Controller ONLY the controller master switch OFF will
force all boom sections OFF.
**
Controller boom switches ON will force boom sections ON
.
Con
troller
Master S
w
itch or
Con
troller
Bo
om Switch
es
or original Boo
m
Sw
itches
Aut
o Boo
m
S
w
itch