Nozzle setup, Pressure setup, Calibr. at 0 psi calibr. at 0 bar – TeeJet 70 Series EPC - Manual Pump User Manual
Page 4: Delta pr 5
2864 Old Rochester Road
Springfield, IL 62703
Phone (217) 753-8424 – Fax (217) 753-8426
www.mid-tech.com
6. Program
Function
Display
Possible actions
Comments
Access
Exit
Push Pro for 3 seconds
Push Pro for 3 seconds
Master must be off
1. Nozzle
nozzle
setup
↓ to select another step
Pro to enter nozzle setup (1.1)
Push Pro for 3 seconds to escape
program
1.1
Iso 04
0.40 g/m
Iso 04
1.31 l/m
↑ ↓ to select a nozzle
Pro to validate selected nozzle
If a programmable nozzle is needed
select programmable nozzle and
push Pro go to step 1.2:
programmable nozzle value.
1.2
@ 40 psi
1.43 g/m
@ 2 bar
1.12 l/m
↑ ↓ to modify gal/min value
Pro to validate value
US Units
Enter nozzle rating in gallons
/ minute @ 40PSI
Metric Units
Enter nozzle rating in liters /
minute @ 2Bar
2. Pressure
sensor
pressure
setup
↑ ↓ to select another step
Pro to enter calibration (2.1)
Push Pro for 3 seconds to escape
program
Maximum pressure allowed
by the sensor.
2.1
Max prs
150 psi
Max prs
10 bar
↑ ↓ to modify max pressure value
Pro to validate max pressure and go
to the zero PSI calibration (2.2)
Max pressure rating for the
sensor can be found on the
sensor or by contacting your
70 series monitor distributor.
2.2
Calibr.
At 0 psi
Calibr.
At 0 bar
Pro for auto calibration of the
pressure sensor at zero PSI
!!! Be sure there is no
pressure in the
system !!!
2.3
Delta pr
5
↑ ↓ to modify value
Pro to validate value
This value is used to compensate
the pressure drop between pressure
measurement point and nozzle.
If not needed, set it to 0.The higher
the value, the higher the
compensation
.