![background image](/manuals/713558/3/background.png)
70 Series EPC - Manual Pump User Guide 98-05073 R1
3. Generality
Function
Key
Description
1. Power
on
Pro
The unit will power on and show the first working screen
US Units
0 psi
0.0 Ga
Metric Units
0 Bar
0.0 lt
2. Power
off
↑ and ↓
The unit will power off
3. Selection
of
working screen
↑ or ↓
The first line on display show dose rate
Second line is user selectable
4. Master
Pump ON/OFF
Pro ON/OFF
If Boom Sense in NOT used Pro can be used to turn
the pump ON/OFF
4. Functionality
Function
Display
Possible actions
Comments
1. Pressure
Flow
When
Master is
ON
15 psi
35.0 gpm
1 bar
35.0 l/m
↑ to increase pump (pressure)
RPM
↓ to decrease pump (pressure)
RPM
Upper line : Actual pressure
Lower line : Actual Flow rate
2. Pressure
Flow
When
Master is
OFF
15 psi
0.0 ga
1 psi
0.0 lt
CLR for 3 second to reset
second line.
Upper line : Actual pressure
Lower line : Accumulated
volume or Total Volume
5. Alarms
Function
Display
Possible actions
Comments
1. No
Pressure
Signal
Error
pressure
CLR to disable alarm
Alarm message will appear on
the second line indicating that
no pressure signal is received;
Check pressure sensor for
damaged or bad connection.
2. No
Pressure
in system
0 psi
no press
0 Bar
no press
CLR to disable alarm
Alarm message will appear on
the second line indicating that
there is no pressure in the
system. Tank could be empty or
pump could be stopped.