Installation of Trim Switch
for RN/RP Gas Valves
1. Thread wire through openings on the right side of
fireplace. Do not cut wire or insulation on metal edges.
2. Slide switch assembly from the back, between subframe
and trim, then fasten the screw. (Fig. 5)
3. For left side installation reverse switch position in
bracket and repeat Step 2. (Fig. 6)
4. Connect wiring to gas valve (Fig. 7a & b) and switch.
CAUTION: Do not wire millivolt remote
wall switch for gas fireplace to a 120v
power supply.
Adjustment of Levelling Bar
(If Required)
1. Determine height of adjustment.
2. Loosen the four (4) screws. (Fig. 8)
3. Set bar at proper height and tighten the screws.
4. Add the two (2) extra screws to prevent any movement.
Venting and Installation
1. The Majestic fireplace may be installed in and
vented through any solid fuel fireplace that has a
minimum fireplace opening 28
³⁄₄
" wide x 21
¹⁄₄
" high x
16" deep and has been installed in accordance with
the National, Provincial/State and local building
codes and is constructed of noncombustible
materials.
2. Only HEDVT (8 x 12) or HEDVT (12 x 12)
termination kit and flex vent kit HEDVK25 or
HEDVK35 is able to be used in this installation.
Under no circumstances should B vent or C vent
be used on this application.
3. Any flue damper must be removed or blocked open.
Trim Top
Left Side Installation
Right Side Installation
Trim Right
Side
Trim
Screw
On/Off Switch
Assembly
Wiring from
Millivolt Gas
Valve
Trim
Screw
Trim Left
Side
On/Off Switch Assembly
FP1253
Fig. 5 Slide switch assembly between subframe and trim.
Bracket Switch
On/Off
Switch
FP1254
Fig. 6 For left side installation, reverse switch position in
bracket.
PILO
T
THTP
TP
TH
SIT Valve
Thermopile
FP382a
Fig. 7a On/Off switch or millivolt thermostat.
TPTH
TH
TP
FP1218
Fig. 7b On/Off switch wiring.
Back of Unit
Levelling Bar
Set Screws
FP1279
Fig. 8 Set levelling bar at proper height and tighten screws.