beautypg.com

Fan kit, Fan removal instructions – Vermont Casting RHEDV25 User Manual

Page 6

background image

6

10000801

Vermont Castings, Majestic Products RHEDV Direct Vent Insert

Always check for gas leaks with a mild
soap and water solution. Do not use an
open flame for leak testing.

it

HI

LO

OFF

PILOT

Thermostat
Bulb

Brass
Plug

Gas Inlet

Manifold Gas
Outlet

Brass Plug

Pressure
Regulator

Control
Knob

Thermocouple Inlet

Pilot Tube Entry

Pilot Adjustment
Screw

Control Knob

Minimum Rate Screw
(Nonadjustable)

HV118

Fig. 2 On fireplaces equipped with the Eurosit 630 gas valve,
there are brass plugs in two of the holes. These plugs are not
to be removed. The gas inlet hole has a plastic cap in it.
Remove the plastic cap and connect your gas supply line at
this point.

115 volt, 60 Hz. 56W

The fan kit includes the following: fan, temperature
sensor, speed control and a 6 ft. cord. The following
explains how to start and set the fan for automatic
operation.

1. Plug in the electrical cord.

2. Start gas fire - see lighting procedures.

3. Turn on fan speed control.

4. Wait until the unit has warmed up sufficiently to

activate the termperature sensor, approx. 5-10
minutes.

Fan Kit

5. Once fan starts, adjust speed control to desired fan

speed. The fan will now automatically come on every
time the fireplace is in operation. Should the fan not
be needed simply turn off the speed control.

The appliance, when installed must be
electrically connected and grounded in
accordance with local codes or, in the
absence of local codes, with the current
CSA C22.1 Canadian Electrical Code.

U.S. Installations, follow local codes and
the National Electrical Code, ANSI/NFPA
No. 70.

Should this fan require servicing, the
power supply must be disconnected. For
rewiring of any replacement components
refer to Figure 4.

Fan Removal Instructions

1. Turn off gas and electricity.

2. Remove the front glass.

3. Remove the logs.

CAUTION: Logs may be hot!

4. Remove burner assembly and rear log support plate.

5. Remove the fan mounting nuts (2 nuts). (Fig. 3)

6. Slip off the electrical connector at the motor.

7. Lift out the fan.

8. To reinstall reverse procedure.

Thermal Sensor is
Attached to Burner
Base

Fan is Installed at
the Back of the
Air Intake Box

Fan Speed Control/Junction Box

Screw
Stud

Screw Stud

FP1252

Fig. 3 Fan location.

Fan

Temperature Sensor

Speed
Control

Black

White

Ground

FP394

Fig. 4 Wiring diagram.

1/2" Gas Supply

1/2" x 3/8" Reducer

3/8" x 3/8" Shut Off Valve

3/8" Union

3/8" Nipple

FP1278

Fig. 1 Typical gas supply installation.