SUUNTO MOSQUITO User Manual
Page 46
44
Fig. 3.20. Decompression dive,
above ceiling. Note downward
pointing arrow, Er warning and
an audible alarm. You should
immediately (within 3 minutes)
descend to or below ceiling.
only after the ASC TIME and CEILING labels have
disappeared, which means that the decompression stop
and any Mandatory Safety Stop has been completed.
You are advised, however, to stay until the STOP sign
has also gone. This indicates that the three minute
Recommended Safety Stop has also been completed.
DISPLAY ABOVE THE CEILING
If you ascend above the ceiling during a decompression
stop, a downward pointing arrow will appear and a
continuous beeping starts (Fig. 3.20.). In addition,
an error warning Er reminds you that you have only
three minutes to correct the situation. You must
immediately descend to or below the ceiling.
If you continue to violate the decompression, the
dive computer goes into a permanent Error Mode. In
this mode the instrument can only be used as a depth
gauge and timer. You must not dive again for at least
48 hours (see chapter 3.2.5.).