beautypg.com

Display below the floor, Display above the floor – SUUNTO D9tx User Manual

Page 86

background image

Display below the floor
The blinking ASC TIME sign and an upward pointing arrow indicate that you are below
the floor. You should start your ascent immediately. The ceiling depth is shown on the
left side, and the minimum total ascent time on the right side of the center window.
Below is an example of a decompression dive without Deep Stops, below the floor.

UPWARD POINTING ARROW, BLINKING ASC

TIME AND AN ALARM TELL YOU TO ASCEND.

MINIMUM TOTAL ASCENT TIME INCLUDING SAFETY

STOP IS 9 MINUTES. CEILING IS AT 3 M.

Display above the floor
When you ascend above the floor, the ASC TIME sign stops blinking and the upward
pointing arrow disappears. Below is an example of a decompression dive above the
floor.

UPWARD POINTING ARROW HAS

DISAPPEARED AND ASC TIME LABEL HAS

STOPPED BLINKING, MEANING YOU ARE IN

THE DECOMPRESSION RANGE.

Decompression will now begin, but is very slow. Therefore, you should continue your
ascent.

87