Ceiling depths: 3.0 to 100 m /10 to 328 ft

Air time: 0 to 99 min (- - after 99)

Temperature display:

Resolution: 1°C/1°F

Display range: -20 to +50°C/-9 to +122°F
Display range: -9 to +50°C/-9 to +122°F

Accuracy: ± 2°C/± 3.6°F within 20 minutes of temperature change

Displays only in NITROX mode:

Oxygen %: 21–99

Oxygen partial pressure display: 0.2–3.0 bar.

Oxygen Limit Fraction: 1–200% with 1% resolution

Logbook/dive profile memory:

Recording interval: 20 seconds adjustable (10, 20, 30, 60 s).

Memory capacity: approximately 42 hours of diving with 20 second recording interval

Depth resolution: 0.3 m/1 ft

Operating conditions:

Normal altitude range: 0 to 3,000 m/10,000 ft above sea level

Operating temperature: 0°C to 40°C/32°F to 104°F

Storage temperature: -20°C to +50°C/ -4°F to +122°F

It is recommended that the instrument be stored in a dry place at room temperature.

NOTE

Do not leave the dive computer in direct sunlight!

96