TROUBLESHOOTING

Problem

Cause

Corrective Action

1. No pilot ignition

- pilot valve not on

• Turn valve to PILOT and depress,

keep match near pilot burner until

ignition.

- gas line not clear

• Inspect supply lines for tube kinks

or obstructions.

- air in gas line

• turn valve to PILOT and depress, keep

match near pilot burner until ignition.

• allow air to purge through the line, may

take up to five (5) minutes.

- no gas supply to the fireplace

• check to see if the fireplace is hooked

to the gas supply.

- no L.P. gas

• fill tank

- main shutoff valve closed

• turn valve on

- valve partially closed

• open valve fully

2. Inadequate flame

- gas line obstruction

• burner inspection for tube kinks or

obstructions.

3. Unit shuts off

- thermocouple is overheating

• reposition logs to keep main burner

flame off the thermocouple assembly.

4. Unit ON/OFF issues

- unit will not turn “ON”

• After the pilot has been lit make

sure to wait

2-3 minutes for flame

to appear.

Make sure to only press button on

remote ONCE, wait for soft beep, after

5 seconds the flame will go out and the

unit will be “OFF” but the pilot light will

still be “ON”.

• If you want to completely turn “OFF”

the unit make sure to turn the Pilot

Control Knob to “OFF” and the Remote

Sensor Switch to “OFF”.

5. Remote control

- low battery detection

• When the transmitter/receiver batteries

transmitter/receiver

(transmitter/receiver)

are low, depressing the ON/OFF key

the light intensity of the LED is weak to

alert of a low battery condition before

losing battery power at all. As soon as

the depleted batteries are replaced, the

transmitter/receiver will restart its

normal operation.