Installation – Sonics 1098 Press User Manual
Page 10
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
I N S T R U C T I O N M A N U A L • M O D E L 1 0 9 8
9
I N S T A L L A T I O N
ELECTRICAL POWER
The press is powered by the power supply. Consult your power supply
instruction manual to determine power specifications.
AIR SUPPLY
The press requires a source of dry, filtered (5 micron), oil-free, compressed
air capable of supplying a constant line pressure of 85 psig. (586 kPa / 6 bar)
at a minimum capacity of 2 CFM.
SETTING UP
The press should be installed in a clear, uncluttered location that is free from
excessive dirt, dust, corrosive fumes, and temperature and humidity
extremes. The selected installation site should be near the electrical power
and air supply sources and away from any equipment that generates
abnormally high electrical transients. Observe the following additional
instructions when installing the press:
a. The press should be placed on a sturdy, level table or bench capable of
supporting a minimum of 500 pounds (227 kg).
b. Allow at least 6 inches (152.4mm) at the rear of the press for cable
connections.
KEY COMPONENTS
Do not connect the press
to an air source supplied
by a compressor lubricated
with synthetic oils or oils
containing phosphate
esters or chlorinated hydro-
carbons. This type of
lubricant may cause the air
filter to malfunction, and
the plastic bowl to rupture.
NOTE: If the power supply
is to be run continuously,
air cooling of the converter
and horn is required. Use
clean, dry compressed air
filtered down to 5 microns
(supplied to converter
fitting).
CONVERTER HOUSING
with converter, booster &
horn (stack) assembly
PALM BUTTONS
CONVERTER
HOUSING DOOR
PART HOLDING
FIXTURE
EMERGENCY STOP
BUTTON
PRESSURE
REGULATOR
& GAUGE
HEAD DOWN
KEY SWITCH
AIR FILTER
(in rear of press)
Go To Top Of Document