15 - technical data – Slant/Fin VSL-160C Part C User Manual
Page 26

98
MODEL
VSL-160-B; VSL-160-C;
Country of destination
USA and Canada
Type of boiler
Direct Vent and room combustion air
Category of discharge chimney
IV
CSA certifi cate N°
2045300 (114696)
Maximum Heat input
Btu/hr
160,000
Minimum heat input
Btu/hr
30,000
Effi ciency at maximum heat input (160°F/140°F)
%
93
Maximum Heat output (160°F/140°F)
Btu/hr
148,800
Effi ciency at minimum heat input (122°F/86°F)
%
97
Minimum heat output (122°F/86°F)
Btu/hr
29,100
Certifi ed AFUE rate
%
91.5
Gas fl ow rate
Natural gas
ft3/hr
156
LP Gas
gal/hr
1.75
Gas supply pressure
Natural gas
In.W.C.
7
LP Gas
In.W.C.
11
Minimum gas supply pressure
Natural gas
In.W.C.
3
LP Gas
In.W.C.
3
Maximum gas supply pressure
Natural gas
In.W.C.
13
LP Gas
In.W.C.
13
Combustion air pressure with min. length
Natural gas
In.W.C.
2.5 to 3.1
LP Gas
In.W.C.
2.1 to 2.7
Combustion air pressure with max. length
Natural gas
In.W.C.
2.1 to 2.7
LP Gas
In.W.C.
1.8 to 2.4
Instantaneous d.h.w production [rise 75°F (42°C)]
gal/min
4.32
Maximum heating temperature
°F
189
Minimum heating temperature
°F
68
Maximum heating pressure
PSI
30
Minimum heating pressure
PSI
8
Maximum pressure of domestic hot water circuit
PSI
150
Minimum pressure of domestic hot water circuit
PSI
1
Capacity of expansion tank (160-C model only)
gal
2.64
Supply voltage
120Vac - 60Hz
Absorbed electric power
W
170
Flue gas pipes diameter (split)
“ (mm)
3.15” (80)
Max. length fl ue gas pipes (split)
ft
300
Flue gas pipes diameter (coaxial)
“ (mm)
2.36/3.94 (60/100)
Max. length fl ue gas pipes (coaxial)
ft
70
Equivalent length of one elbow
ft
45° elbow = 3ft, 90° elbow = 5ft
CO (Carbon monoxide) with natural gas
ppm
<150
CO (Carbon monoxide) with LP gas
ppm
<250
NOx (0% O2 with natural gas)
ppm
<30
CO2 (Carbon dioxide) for Natural gas at high fi re
%
9.1 to 9.3
CO2 (Carbon dioxide) for Natural gas at low fi re
%
8.4 to 9
CO2 (Carbon dioxide) for LP gas at high fi re
%
9.3 to 9.7
CO2 (Carbon dioxide) for LP gas at low fi re
%
9.2 to 9.8
O2 (Oxygen) for Natural gas at high fi re
%
4.4 to 4.6
O2 (Oxygen) for Natural gas at low fi re
%
5.1 to 5.7
O2 (Oxygen) for LP gas at high fi re
%
5.7 to 5.9
O2 (Oxygen) for LP gas at low fi re
%
6.1 to 6.7
Ionisation current
71 to 90
Maximum fl ue gas temperature
°F
210
Flue gas mass-fl ow
lb/hr
160
Head pressure available for fl ue vent/air intake line
In.W.C.
3.6
Maximum condensation fl ow rate
gal/hr
1.32
Average acidity of condensation
PH
4
Boiler weight (empty of water) (160-C model)
lb
125
Boiler weight (empty of water) (160-B model)
lb
93
15 - TECHNICAL DATA