11. Removing and replacing the bolt assembly
WARNING:
B e f o re perf o rming any cleaning
or maintenance, make sure there are
no cartridges in the chamber or
magazine.
11.1 Removing the bolt assembly
• Unload the rifle (see chapter 10).
• Remove the magazine.
• Pull the bolt assembly all the way back.
• Push down and hold the bolt stop pin
(fig. 12) and simultaneously withdraw
the bolt assembly backwards with the
other hand.
11.2 Installing the bolt assembly
• Carefully position the ends of the two
slide rails onto the rear end of the
receiver in line with the bolt guide.
• slide the bolt assembly forward into
the receiver.
• Close the bolt by pushing the bolt han-
dle forward.
NOTE:
Do not use force when doing this!
If the bolt assembly does not slide on
smoothly, try again taking more care.
fig. 12
WARNING:
If you are having trouble closing the
bolt, stop immediately. Do not force a
round into the chamber, check to make
sure that the ammunition is the correct
caliber, that is not defective, or that an
obstruction does not exist in the bore
or chamber. If the problem still exists,
return your rifle, unloaded, to
SIG Arms™.