Mounting the scope – SIG SAUER BLASER K95 User Manual
Page 20

20
5. Mounting the scope
The K 95 has been prepared for the
original Blaser saddle mount (DBP). We
assume that an authorized dealer has
fitted your scope correctly to match the
barrel.
5.1. Mounting the scope:
- Flip the covers of the front and rear
locking lever open, ensuring that both
of them are swivelled fully forward/up.
- Grip the rifle at the fore-end with your
left hand and support stock on your
thigh.
- Grip the scope at the centre tube above
the mount with your right hand in such
a manner, that you can reach the front
locking lever with your thumb.
- Carefully place the two round pins of
the scope mount into the two oval
notches in the upper right side of the
barrel. Tilt scope to the left and keep
it in this position.
- First press the front and then the rear
mounting lever (which were flipped
open previously) backwards/down with
your thumb, until they reach the stop
(tension). If this can be done too easily
or only by using considerable force,
then the mounts are set incorrectly. In
either case, have your authorized dealer
correct this to specification.
- Close the two saddle covers of the
locking levers now.
Ensure that the mounting surfaces are
clean and free from oil.
K95 English 2001 6/8/01 2:40 PM Page 20