PRESSURIZED FRESH WATER SYSTEM
1 . Drain potable water tank and empty holding tank .
2 . Add freshwater antifreeze to potable water tank .
3 . Flush potable water antifreeze and water mixture through toilet(s) and into entire system,

including the waste holding tank, diverter valve connections, discharge pumps, etc . Turn off

power to toilet .

Each installation is different, so amounts may vary . User discretion is required to assure

adequate protection .

RAW WATER SYSTEM
Parts required:

• Hose that fits raw water pump, about 3 ft. (1 m) long

• one container

1 . Close intake and discharge seacocks . See Hazard of Flooding risks in this manual .
2 . Turn off power to toilet .
3 . Disconnect and drain intake hose and in-line filters .
4 . Connect hose to raw water pump intake .
5 . Place hose connected to pump intake into bucket with antifreeze in it .
6. Turn on power to toilet and flush until antifreeze is removed from toilet.
7 . Disconnect power to toilet and reconnect all intake and drain hoses .