Hose Installation

Dometic Holding Tanks

• Vent fitting on Dometic holding tank will accom-

modate 16 mm ID vent hose .

• Install a Dometic vent filter in the vent line to

absorb malodorous gases, letting only freshened
air out of the vent .

Item

Description

1

Vent hose

2

Vent filter

3

Holding tank

Note
Vent line must not have any low runs that
can create a liquid trap .

Vent Hose (fig. 9 , page 5)

9

Do not restrict the ability to pull the hose or pipe (fig. 10 A, page 6).
Avoid binding corners and sharp bends ( fig. 10 B, page 6).
Do not use wire ties to secure hose or pipe . Support flexible hose every 0 .3 m (12 inches) and
support rigid pipe every 1 .5 m (5 feet) .
Where possible use a support trough under the hose or pipe (fig . 10 C, page 6) .

Bulkhead Penetrations (fig. 11 , page 6)
Check each side of a bulkhead to ensure that there will be no cutting into:
• fuel or water tanks
• wiring or pipes
• reinforcement stringers (4) that support the hull

When creating new holes, avoid tabs (1) and stringers (4) that hold bulkheads or partitions in place .
Provide additional reinforcement so that structural integrity is not compromised .
• avoid (2)
• possible (3)

Hose and Heat Sources
The operating temperature of flexible hose prohibits exposure to sources of high or direct heat, such
as light bulbs or engine manifolds . If any part of the hose system must be run close to a heat source,
use rigid pipe instead of hose .

When connecting flexible hose to plastic fittings (fig . 12 , page 7), use special hose lubricant which is
supplied with the Dometic holding tank. Apply lubricant around end of fitting and inside end of hose
that connects to fitting . The Dometic lubricant makes connections easier . Do not use any other
lubricant, sealant or adhesive .

Hose Clamps (fig. 13 , page 7)
Each hose connection should be secured with two hose clamps to prevent possibility of leaks .
Position the clamp screws 180° apart from each other and tighten the clamp . Do not over-tighten
clamps or they may cut into the hose . If over-tightening is the only way to stop a leak, the hose-
to-fitting connection is not sized correctly, and an adapter or different size fitting is required .

6.3

Recommended hose installation methods

6.4

Connecting hose to plastic fittings

10

12

10

10

11

13