Scientech S9000 User Manual

Page 15

background image

15

[decimal number]_CONVERT[CR]

None

Loads the number entered, as a "last

front panel units" relative multiplier,

into the CONVERT register and enters

the CONVERT mode. CLEAR exits the

convert mode and undefines the convert

register.

[decimal number]_CAL[CR]

None

Loads a computed number based on the

entered number, as a "last front panel

units" relative multiplier, into the CAL

register and enters the CAL mode. The

display must be non-zero when this

command is issued. If the display is

zero, a 3 second "Err" message is

displayed and the balance returns to its

normal weighing mode. The current

weight reads as the number entered with

the appropriate sign. CLEAR exits the

CAL mode and undefines the CAL

register.

[integer]_PIECES[CR]

None

Loads a computed number based on the

entered number, as a "last front panel

units" relative multiplier, into the

PIECES register and enters the PIECES

mode. The display must be non-zero

when this command is issued. If the

display is zero, a 3 second "Err"

message is displayed and the balance

returns to its normal weighing mode.

CLEAR exits the pieces mode and

undefines the pieces register.

[Decimal

number]_ENTER_[integer]

_PIECES[CR]

None

Accepts the decimal number as a weight

in "last front panel units" per integer

pieces. If the balance is not in PCS

mode, it goes into PCS mode using the

decimal number/the integer as the

weight. If used when the balance is

already in PCS mode, the display digits

are blanked for about 1 second while the

PCS an "last front panel units"

annunciators are lit. The balance then

resumes normal PCS operation using the

decimal number/the integer as the unit

weight.

[register number]_RCL_[(CONVERT)

(CAL) (PIECES)][CR]

REG XXX :[register contents][MULT.]

Puts the recalled register contents into

the specified mode register and enters

that mode.

TAVG[CR]

None

Clears the TBAR registers and enters

the TBAR mode.

RESET_TAVG[CR]

None

Clears the TBAR registers. If the

balance is in the TBAR mode, the

process keeps running.

XAVG[CR]

None

Accumulates the current weight in the

XBAR registers.

RESET_XAVG[CR]

None

Clears the XBAR registers.

GLP[CR]

Sends GLP header

Puts balance in the GLP mode.

XAVG[CR]

Sends weight while in GLP

Accumulates the current weight in the

XBAR registers.

RCL_XAVG[CR]

Sends statistics and signature line

Terminates GLP mode.

ISO[CR]

Sends ISO header and waits for target

weight entry

Puts balance in ISO mode.

xxx.xx_Targ[CR]

Sends target weight (g)

Enter target weight value in grams.