the blower and motor. Buildup of dust on the blower
and motor can create excessive loads on the motor
resulting in higher than normal operating temperatures
and possible shortened service life.

Air Filters

WARNING:

Never operate the unit without a fi lter in the
return air system. Dust and lint in the return
air can build up on the internal components,
resulting in loss of efficiency, equipment
damage, and possible fi re risk.

Q6SP S

eries units are factory equipped with pleated

2 inch disposable fi lters. The fi lters should be checked
periodically and replaced (or cleaned) when necessary
with fi lters of the same dimensional size. Replace
using disposable fi lters with a minimum airfl ow rating
of 500 FPM or permanent fi lters only.

• The fi lter rack is fi eld adjustable to accommodate 1”

permanent fi lters. DO NOT use 1” disposable fi lters in
these units.

• Always replace the fi lter access panels after changing

or cleaning the fi lters. DO NOT operate unit without
the fi lter access panels in place.

• It is very important to replace or clean the fi lter(s)

installed in the return air duct of this system. A clogged
fi lter could cause airfl ow related problems and reduce
the overall effi ciency of your unit. Always replace
disposable fi

lter(s) installed in your system only

with the same size dimensional fi lters that are being
replaced.

• Filters must be ULC approved or equivalent for use in

Canada.

Motor Lubrication

The motors for the circulating air blower and outdoor fan
are pre-lubricated and sealed by the manufacturer. No
further oiling is required for the life of this product.

TROUBLESHOOTING

Before you call a Technician, check the following:
• Check the thermostat setting. Make sure the system

mode and temperature settings are correct.

• Check the electrical panel for tripped circuit breakers.
• Check the fi lters for dust accumulation.
• If the items above don’t resolve your problems, then

call your nearest service technician.

¢708760.¤

WARRANTY INFORMATION

A warranty certifi cate with full details is included with the
equipment. Carefully review these responsibilities with
your dealer or service company. The manufacturer will not
be responsible for any costs found necessary to correct
problems due to improper setup, improper installation,
adjustments, improper operating procedure on the part
of the user, etc.

Some specifi c examples of service calls which are not
included in the limited warranty are:
• Correcting wiring problems in the electrical circuit

supplying the equipment.

• Resetting circuit breakers or other switches.
• Adjusting or calibrating of thermostat.