beautypg.com

Section iii operation, General information, Power, fail safe operation (1) – PS Engineering PMA6000B User Manual

Page 16: Section iii operation -1, General information -1, Power, fail safe operation (1) -1, Figure 3-1 pma6000b without marker (-0100) -1, Figure 3-2 pma6000b with marker (-0300) -1, 2 power, fail safe operation (1)

background image

PS Engineering

PMA6000B Audio Selector Panel and Intercom System

Installation Manual

200-066-0200

Page 3-1

Rev 6, Feb. 2013

Section III OPERATION

GENERAL INFORMATION

3.1

GENERAL INFORMATION

This section provides detailed operating instructions for the PS Engineering PMA6000B, Audio Selector
Panel/Intercom Systems. Please read it carefully before using the equipment so that you can take full ad-
vantage of its capabilities.

This guide is divided into sections covering the basic operating areas of the PMA6000B systems. They
are: Audio Selector, Audio Selection, Intercom, and Marker Beacon Receiver (if equipped).

Figure 3-1 PMA6000B without Marker (-0100)

Figure 3-2 PMA6000B with Marker (-0300)

3.2 Power, Fail Safe Operation (1)

Unit power is turned on and off by pressing the unit Volume control knob (smaller concentric knob on left
side of unit) In the

OFF

or "

FAIL

-

SAFE

" position, the pilot is connected directly to Com 1 and unswitched

input #1, allowing transmit receive and alert capability regardless of unit condition. Any time power is
removed or turned

OFF

, the audio selector will be placed in the fail-safe mode. In fail-safe mode, the pilot

headset is connected directly to Com 1.