INSTALLATION INSTRUCTIONS

Fig.4

Correct orientation

of Installation Plate

Wall

Indoor

Outdoor

5-

7m

m

Fig.6

Fig.5

Indoor unit installation (wall-mounted type)

2. Drill a hole in the wall

Note:

1. Fit the Installation Plate

1. Fit the installation plate horizontally

on structural parts of the wall with

spaces around the installation plate.

2. If the wall is made of brick, concrete

or the like, drill five or eight 0.197 inches ( 5mm)

diameter holes in the wall. Insert Clip anchor

for appropriate mounting screws.

3. Fit the installation plate on the wall

with five or eight type “A” screws.

Fit the Installation Plate and drill

holes in the wall according to the

wall structure and corresponding

mounting points on the installation

plate. The Installation Plate may be

slightly different according to the

different models of indoor unit.

(Dimensions are in “inch” unless

otherwise stated)

1. Determine hole positions according

to the diagram detailed in Fig.5. Drill

one (1) hole (2.5 inches (65mm)) slanting slightly

to outdoor side.

3. Connective Pipe and Drainage
Installation

1. Run the drain hose sloping downward.
Do not install the drain hose as
illustrated in Fig.7.

Drainage

Fig.7

Do not block water flow by a rise.

Do not put the end of

drain hose into water.

Indoor unit outline

Installation plate

11

.5

in

.

Right rear side

refrigerant

pipe hole 2.6in.

Left rear side

refrigerant

pipe hole 2.6

36.14in.

1.

8

7.28in.

5.91in.

A

1.

8

B

Right rear side

refrigerant

pipe hole 2.6in.

Installation plate

Indoor unit outline

Left rear side

refrigerant

pipe hole 2.6

6in.(150mm) or more to ceiling

4.8in.(120mm)

or more to wall

4.8in.(120mm) or

more to wall

Model A (A: 28, B: 9.84, C:3.94, D: 4.33)

Model A (A: 28, B: 9.84, C: 3.94, D: 4.33)

Model A (A: 36.2, B: 11.5, C:5.9, D: 7.3)

Model B(

)

A: 31.1, B:10.43, C:3.94, D: 5.9

Model B(

)

A: 31.1, B:10.8, C:3.94, D: 3.35

Model C(

)

A: 33.5, B:11.4, C:3.94, D: 4.53

Model B(

)

A: 39.2, B:11.5, C:5.9, D:7.9

Model C(

)

A: 33.5, B:12, C:5.9, D:5.7

1.

8

C

D

6in.(150mm) or more to ceiling

4.8in.(120mm) or

more to wall

4.8in.(120mm)

or more to wall

Right rear side

refrigerant

pipe hole 2.6in.

Left rear side

refrigerant

pipe hole 2.6in.

1.

8

1.

8

6in.(150mm) or more to ceiling

4.8in.(120mm) or

more to wall

4.8in.(120mm)

or more to wall

1.

8

0

.2

-0

.3

in

.

(

)