Four-way cassette type, 9installation instructions, Necessary room – Perfect Aire 1PAMSH36-MZO4-16 Installation Manual User Manual

Page 10: Attached fittings

background image

2. Four-way cassette type

1. Decide the correct carry-in path.

2. Move this unit as originally packaged as possible.

3. If the air conditioner is installed on a metal part

of the building, it must be electrically insulated

according to the relevant electrical code.

4. If installing phase protectors at a high position

where it is hot and humid with frequent thunder-

storms, lightning-protection equipment is necessary.

Notes before installation

1. Install the main body

A. The existing ceiling (to be horizontal)

a. Please cut a square hole of 24 x 24 inches.

in the ceiling according to the shape of the

installation paper board. (Refer to Fig.15 & 16)

The center of the hole should be at the same

position of that of the air conditioner body.

Determine the lengths and outlets of the conn-

ecting pipe, drain pipe and cables.

To balance the ceiling and to avoid vibration,

please enforce the ceiling when necessary.

b. Please select the position of installation hooks

according to the hook holes on the installation

board.

Drill four holes of 0.5 inches (12mm), 2.5 inches (50~55mm)

deep at the selected positions on the ceiling. Then embed

the expansible hooks (fittings).

Face the concave side of the installation hooks

toward the expansible hooks. Determine the

length of the installation hooks from the height

of ceiling, then cut off the unnecessary part.

If the ceiling is extremely high, please determine

the length of the installation hook according to

facts.

Indoor unit installation

9

INSTALLATION INSTRUCTIONS

Please check whether the following fittings are of full scope. If there are some attached fittings free
from use, please restore them carefully.

11. Expansible hook..............................4

12. Installation hook..............................4

8. Installation paper board.....................1

13. Orifice.............................................1

Attached fittings

9. Soundproof / insulation sheath.........1

10. Seal ring..........................................1

3. Remote Control................................1

14. Frame.............................................1

15. Mounting screw (ST2.9 10-C-H) ...2

4. Alkaline dry batteries (AM4)............2

1.Installation manual.................................1

A

1

1

in

.

Necessary room

Fig.13

Fig.14

Ground

Outlet

Outlet

>9

0.

6i

n.

Inlet

Fig.15

(on some models)

>3

9.

4i

n.

>39.4in.

>39.4in.

>3

9.4

in.

2.Owner's manual.....................................1

5.Outlet pipe sheath ..............................1
6.Outlet pipe Clasp ...................................1

7.Drain joint .............................................1

(on some models)

21.5 in.

22.5in

25.5in.

20

.7

in

.

22

.5

in

.

25

.5

in

.