QuickSpecs


ProLiant BL20p and p-Class system

DA-11411

Canada — Version 1 — August 26, 2002

8

Standard Features

Compaq ProLiant BL p-Class Server Blade Enclosure and Interconnects

(continued)

Security

Power-on password

Administrator's password

Integrated Lights-Out has 12 customizable user accounts and SSL encryption

Integrated Lights-Out can be disabled via a Global Setting

Interconnect Switch multilevel user names and passwords and management interface time out period setting

Up to 64 Port-based IEEE 802.1Q tagged VLANs per interconnect switch


Minimum Rack Requirements

Mounts in Compaq, and Telco racks and Third Party racks that meet the following criteria:

Compatible with 19-inch Standard EIA rail sets

EIA rail-to-rail depth is 29

30

Cabinet depth must be at least 36-inch deep overall (Additional min. 3.5-inch clearance from rear

RETMA rail to rear door, inclusive in the 36-inch overall depth)

Ample room for top and bottom cable egress (approximately 8 square inches for full rack configuration

with patch panel)

Must be capable of supporting 1600 lb (for full rack configuration)

Perforated front and rear doors to accommodate front-to-back cooling

Must have 65% open perforation on server blade enclosure doors to support airflow requirements

Optimized for use with the Compaq 10000 Series racks

Note: If using Compaq 7000 Series rack, Compaq Rack Extension Kit and High Air Flow Rack Door options are

required.


Rack Airflow Requirements

Rack 9000 and 10000 series Cabinets

The increasing power of new high-performance processor technology requires increased cooling

efficiency for rack-mounted servers. The Compaq 9000 Series Rack and the new 10000 Series Racks

provides enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers

using the latest processors.

Rack 7000 series Cabinets

When installing a server with processors running at speeds of 550 MHz or greater in Compaq Rack

7000 series racks with glass doors (165753-001 (42U), and 163747-001 (22U)), the new processor

technology requires the installation of Compaq’s new High Airflow Rack Door Inserts (327281-B21

(42U), 327281-B22 (42U 6 pack), or 157847-B21 (22U)) to promote enhanced airflow for maximum

cooling.

CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow

and to prevent damage to the equipment:

o

Front and rear doors: If your 42U server rack includes closing front and rear doors, you must

allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit

adequate airflow (equivalent to the required 64 percent open area for ventilation).

o

Side: The clearance between the installed rack component and the side panels of the rack must

be a minimum of 2.75 inches (7 cm)

CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This

arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling

that can lead to thermal damage.

Note: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with

the server, or to the server documentation located in the Support section at the following URL:

http://www5.compaq.com/products/servers/proliantdl380/index.html

.

Note: This Web site is available in English only.