beautypg.com

Quickspecs, Technical specifications, Proliant bl20p and p-class system – Compaq ProLiant p-Class User Manual

Page 19

background image

QuickSpecs


ProLiant BL20p and p-Class system

DA-11411

Canada — Version 1 — August 26, 2002

19

Technical Specifications

Dimensions

Height

10.405 in/26.43 cm

Width

1.535 in/3.899 cm

Operating and Performance
Specifications for Interconnect
GbE Switch

Depth

27.697 in/70.35 cm

Weight

11.5 lb/5.2 kg per interconnect switch

Performance

3.2 Gbps Switching bandwidth per server enclosure

4.4 Gbps uplink bandwidth per server enclosure

9.6 Million pps aggregate throughput per server enclosure (64-byte packets)

Full-wire speed for all connections

Auto-negotiation and auto-sensing with full-duplex support

Forwarding mode

Store and forward

MAC Addresses

8,191 per interconnect switch; MAC address based filtering and MAC address
packet priority configuring

Forwarding table age time

Maximum age: 10 to 9999 seconds; default: 3000 seconds

Memory

32MB Main, 6MB flash and 16MB packet buffer per interconnect switch

Compliance

IEEE 802.3, 802.3u, 802.3ab, 802.3z, 802.1D, 802.1p, 802.3ac, 802.3ad
(Static), 802.1Q, and 802.3x

SNMP v1 (RFC 1157) and RMON v1 (RFC 1757) groups 1, 2, 3, and 9

MIB-II (RFC 1213), Bridge MIB (RFC 1493), Interface MIB (RFC 2233),
801.1Q MIB (RFC 2684), RMON1 MIB (RFC 1757) groups 1, 2, 3, and 9, and
Ethernet MIB (RFC1643)

Network transfer rate

10 Base-T (half-duplex)

10 Mbps

10 Base-T (full-duplex)

20 Mbps

100 Base-TX (half-duplex)

100 Mbps

100 Base-TX (full-duplex)

200 Mbps

1000 Base-TX (half-duplex)

1000 Mbps

1000 Base-TX (full-duplex)

2000 Mbps

1000 Base-SX (full-duplex)

2000 Mbps

Connector

RJ-45, DB-9 (C-GbE Interconnect Kit)
LC fiber, RJ-45, DB-9 (F-GbE Interconnect Kit)

EMI

FCC Class A

ICES-003 Class A

AS/NZS 3548 Class A

VCCI Class A

Safety

UL/CUL Listed Accessory

Power requirements

48V: 1050 mA, 50 W maximum (per interconnect switch)

Temperature range

Operating

50° to 95° F/10° to 35° C

Non-operating

-22° to 140° F/-30° to 60° C

Operating

20% to 80%

Relative humidity
(non-condensing)

Non-operating

5% to 95%

Operating

82.4° F/28° C

Wet bulb temperature

Non-operating

101.7° F/38.7° C

Note: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight. Upper

operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/ 9,144 m or

30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of

113° F/45° C. Altitude maximum for storage is 70 KPa.