beautypg.com

Technical specifications, Quickspecs, Proliant bl20p and p-class system – Compaq ProLiant p-Class User Manual

Page 17

background image

QuickSpecs


ProLiant BL20p and p-Class system

DA-11411

Canada — Version 1 — August 26, 2002

17

Technical Specifications

Dimensions

Height

10.5 in /26.67 cm

Compaq ProLiant BL p-Class

Server Blade Enclosure

Width

17.60 in/44.70 cm

Depth

28.86 in/73.30 cm

Rated input voltage

-43 VDC to -53 VDC Nominal -48 VDC

Rated input current

62.5 A at -48 VDC

Input Specifications

Rated input Power

3000 W

Rated input voltage

-43 VDC to -53 VDC Nominal -48 VDC

Individual server blade bay
ratings

Rated input current

6.25 A at -48 VDC

Rated input Power

300 W

Temperature range

Operating

50° to 95° F/10° to 35° C

Non-Operating

-22° to 140° F/-30° to 60° C

Operating

20% to 80%

Relative humidity
(non-condensing)

Non-Operating

5% to 95%

Wet bulb temperature

Operating

82.4° F/28° C

Non-Operating

101.7° F/38.7° C

Note: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight.

Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/ 9,144
m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of
113° F/45° C. Altitude maximum for storage is 70 KPa.


Dimensions

Height

1.69 in/4.29 cm

Operating and Performance

Specifications for ProLiant BL20p Server

Blade

Width

10.29 in/26.14 cm

Depth

28.00 in/71.12 cm

Weight (maximum)

18.0 lb/8.17 kg

Temperature range

Operating

50° to 95° F/10° to 35° C

Non-operating

Shipping

-40° to 140° F/-40° to 60° C

Storage

-4° to 140° F/-20° to 60° C

Operating

10% to 90%

Relative humidity
(non-condensing)

Non-operating

Shipping

10% to 90%

Storage

10% to 95%

Maximum wet bulb
temperature

82° F/28° C

Note: Operating temperature has an altitude derating of 34° F/1° C per 1,000 ft/304.8 m. No direct sunlight.

Upper operating limit is 10,000 ft/3,048 m or 70Kpa/10.1 psia. Upper non-operating limit is 30,000 ft/ 9,144
m or 30.3 KPa/4.4 psia. Storage maximum humidity of 95% is based on a maximum temperature of
113° F/45° C. Altitude maximum for storage is 70 KPa.