beautypg.com

3 post-calibration check – NORAC UC5-BC-RG11 User Manual

Page 39

background image



36

13.3 Post-Calibration Check

1. Put the system into Auto Mode by pressing the “A” button. The boom should level out.

Put the system back into Manual Mode by pressing the “M” button.

2. Verify that the sensor heights are correct. Measure the distance from the lowest point of

the boom to the ground near each sensor. 

With the system in Manual Mode, select the Settings button

(wrench).

Select the Next button (right arrow).

Select the Next button (right arrow).

Select the Setup button.

Select Sensor Setup.

Select each sensor position and verify that the height reading
matches the measured distance.

The reading can be changed by selecting the reading and
entering the appropriate height.