beautypg.com

7 roll sensor installation, 1 bracket assembly – NORAC UC5-BC-RG11 User Manual

Page 19

background image



16

7 Roll Sensor Installation

7.1 Bracket Assembly

1. Securely mount the roll sensors to the included roll sensor brackets using the #6 machine

screws. Tighten screws to 10 in-lbs (1.1 Nm).

2. The orientation of the mounted roll sensor to the roll sensor bracket will depend on the

bracket mounting. The roll sensor CANbus connector must be pointing towards the right
side of the sprayer (when looking from the rear of the sprayer).

Figure 12: Mounting Roll Sensor to Bracket


Figure 13: Roll Sensor Orientation - Connector Facing Right Wing