8.3 Input Module

1. Install the input module (E03) on the sprayer near the NORAC valve block. Secure it to

the boom using cable ties or optional brackets.

2. Connect the free end of the CANbus cable (C02) from the valve module to the input

module.

3. Insert the 12 pin plug (P02) into the OEM 3 connector on the end of the input module

4. Connect the 12 pin connector on the tilt interface cable (C20) to the Thru 2 connector on

the side of the input module.

5. Insert the connectors on the other end of C20 into the tilt connectors.

Figure 22: Input Module Connections

6. Connect the 12 pin connector on the main lift interface cable (C21) to the Thru 1

connector on the side of the input module.

7. Insert the connectors on the other end of C21 into the main lift connectors on the sprayer

solenoids.

Alternate cabling is available from NORAC if the connectors on C20 and C21 do
not match the valve block. Refer to Section 4.6 for ordering information.