8 module installation, 1 control module – NORAC UC5-BC-RG06 User Manual
Page 24
21
8 Module Installation
An optional module mounting bracket kit is available for purchase from NORAC. The
mounting brackets are compatible with control modules and input modules. One kit is needed
per module.
Item
Part Number
Name
Quantity
B20
43708
UC5 MOUNTING BRACKET KIT (CONTROL AND INPUT MODULES)
1
8.1 Control Module
1. Refer to Figure 1 and Figure 17.
2. Securely mount the control module (E01) inside the sprayer cab, using screws, cable ties or
optional brackets.
3. Connect the display terminal to the control module using the display cable. This cable must
be connected to the end of the control module with only one Deutsch connector.
4. Connect the power cable (C30) to one of the two CANbus connectors on the control
module. Connect the other end of the power cable to an appropriate power source.
5. Route cable C01 from the other CANbus connector towards the rear of the sprayer.
6. There is an access panel located on the front right corner of the Rogator cab floor. It can
be removed to allow cables to be routed to the exterior of the cab. Use this panel to
route C01 through the hole of the provided access panel kit (Figure 17).
Figure 17: Control Module Mounting