beautypg.com

4 wing sensor installation – NORAC UC5-BC-JD12 User Manual

Page 16

background image



13

6.4 Wing Sensor Installation

1. The sensor bracket should be oriented forward (ahead of the boom).

2. Typically the best mounting location for the wing sensor brackets will be near the end of

the boom tips, approximately two feet (60cm) from the end.

3. Depending on the boom design, some breakaway sections will lift upwards as they break

back. If the sensor is mounted to this portion of the boom, the system will force the boom
downwards towards the ground as the boom folds backwards.

4. Use M07, M08 and M09 in place of the supplied hardware to mount the brackets.

5. Mount the NORAC UC5 ultrasonic sensor into the sensor bracket and run the sensor

cable either through hole in the back or through the side cut-out and behind the bracket.
Ensure the cable is clear of moving parts and will not be damaged during folding.

Figure 8: Bracket Mounting Example

Figure 9: Wing Bracket Mounting

Front