beautypg.com

8 connecting the sensors to the canbus – NORAC UC5-BC-HD08A User Manual

Page 28

background image



25

8 Connecting the Sensors to the CANbus

1. Connect cable C01 from the valve module to the 8-way coupler (E11).

2. Connect the main lift sensor to the 8-way coupler using cable C01 and a 2-way coupler

(E12). Cable C01 and item E12 may not be needed if the 8-way coupler is mounted close
enough to the main lift sensor.

3. Connect the sensor on the linear roll cylinder to the 8-way coupler using cable C01 and a

2-way coupler (E12).

4. Connect cables (C01) between the 8-way coupler and a 2-way coupler (E12). Connect the

cables (C05) to the 2-way coupler and route along the booms to the wing sensors.

5. At the sensor brackets, attach a 2-way coupler with terminator (E20) to the sprayer boom.

The 2-way coupler with terminator is the white two way coupler. Plug the sensor and the
CANbus cable (C05) into the 2-way coupler.

6. Insert the 6-pin plugs (P03) into the unused connectors on the 8-way coupler.

Follow existing cables and hoses to be sure the cable will not be pinched or
stretched.
Ensure that all unused connectors are plugged with the plugs provided.