8 connecting the sensors to the canbus – NORAC UC5-BC-HD08A User Manual
Page 28
25
8 Connecting the Sensors to the CANbus
1. Connect cable C01 from the valve module to the 8-way coupler (E11).
2. Connect the main lift sensor to the 8-way coupler using cable C01 and a 2-way coupler
(E12). Cable C01 and item E12 may not be needed if the 8-way coupler is mounted close
enough to the main lift sensor.
3. Connect the sensor on the linear roll cylinder to the 8-way coupler using cable C01 and a
2-way coupler (E12).
4. Connect cables (C01) between the 8-way coupler and a 2-way coupler (E12). Connect the
cables (C05) to the 2-way coupler and route along the booms to the wing sensors.
5. At the sensor brackets, attach a 2-way coupler with terminator (E20) to the sprayer boom.
The 2-way coupler with terminator is the white two way coupler. Plug the sensor and the
CANbus cable (C05) into the 2-way coupler.
6. Insert the 6-pin plugs (P03) into the unused connectors on the 8-way coupler.
Follow existing cables and hoses to be sure the cable will not be pinched or
stretched.
Ensure that all unused connectors are plugged with the plugs provided.