beautypg.com

NORAC UC5-BC-HD08A User Manual

Page 27

background image



24

7. Connect hoses to the linear roll cylinder using two 6MB 6MOR (F05) fittings.

8. Install tee fittings onto the “A” and “B” ports of the 3rd station of the NORAC block.

9. Connect a hose from the “SG” port on the HARDI valve block to the tee fitting on the “B”

port of the 3rd station of the NORAC block

10. Connect the hose from the port on the barrel of the linear roll cylinder to the tee fitting on

the “B” port of the 3rd station of the NORAC block.

11. Connect a hose from the “SA” port on the HARDI valve block to the tee fitting on the “A”

port of the 3rd station of the NORAC block.

12. Connect the hose from the port on the rod of the linear roll cylinder to the tee fitting on

the “A” port of the 3rd station of the NORAC block.