7 hydraulic installation, 1 valve assembly – NORAC UC5-BC-HD08A User Manual
Page 20
17
7 Hydraulic Installation
Ensure all pressure has been bled from the system before disconnecting any lines
or fittings. Hydraulic pressure will exist on the wing tilt circuits unless the wings
are being supported by other means. The hydraulic installation may be performed
with the wings in transport position, resting on the ground or with the tilt cylinders
fully extended.
Component failure due to oil contamination is not covered under the NORAC UC5
system warranty. It is recommended that a qualified technician perform the
hydraulic installation.
7.1 Valve Assembly
1. On a clean surface remove the plastic plugs from the block.
2. Install two 6MB 6MOR (F05) fittings into the “P” and “T” ports on the NORAC block.
Tighten to 18 ft-lbs (24 Nm).
3. Install two 6MB 6MOR (F05) fittings into the “B” ports on the NORAC block. Tighten to
18 ft-lbs (24 Nm).
4. Install the 6MBP (F03) plugs into the “A” ports on the NORAC block and tighten to 18 ft-
lbs (24 Nm).
5. Install the orifice (F04) into the “B” port of third station of the NORAC block with the
notch facing in. Install the orifice (F06) into the “A” port of third station of the NORAC
block with the notch facing in. Install two 6MB 6MOR (F05) fittings into the “A” and
“B” ports of the 3
rd
station on the NORAC block. Tighten to 18 ft-lbs (24 Nm).
Figure 18: NORAC Valve Block Details