9

4.3 H

YDRAULIC

I

NSTALLATION

4.3.1 Valve Mounting
1. On a clean surface remove all plastic

plugs from the NORAC hydraulic Valve
(V01) (Figure 9).

Figure 9: NORAC Valve Block

2. Install the orifices (F06) into the “B”

ports with the notch facing outward
as shown in Figure 10.

Figure 10: Valve Block Assembly

3. Install the 6MB-6MJ fittings (F04) into

the “B” ports and tighten to 18 ft-lbs.

4. Install the 6MB-plugs (F05) into the “A”

ports and tighten to 18 ft-lbs.

5. Insert the 0.047” orifice (F06) into the

“A” port of the 3

rd

station of the block

with the notch facing in (Figure 10).

6. Insert the 0.042” orifice (F07) into the

“B” port of the 3

rd

station of the block

with the notch facing in (Figure 10).

7. Mount the 6MB-4MOR fittings (F04)

into the “A” and “B” ports on the
NORAC 3

rd

station portion of the

block.

8. Mount the NORAC valve (V01) to the

sprayer in a suitable location.